With the growing numbers of nanomaterials (NMs), there is a great demand for rapid and reliable ways of testing NM safety—preferably using in vitro approaches, to avoid the ethical dilemmas associated with animal research. Data are needed for developing intelligent testing strategies for risk assessment of NMs, based on grouping and read‐across approaches. The adoption of high throughput screening (HTS) and high content analysis (HCA) for NM toxicity testing allows the testing of numerous materials at different concentrations and on different types of cells, reduces the effect of inter‐experimental variation, and makes substantial savings in time and cost. HTS/HCA approaches facilitate the classification of key biological indicators of NM‐cell interactions. Validation of in vitro HTS tests is required, taking account of relevance to in vivo results. HTS/HCA approaches are needed to assess dose‐ and time‐dependent toxicity, allowing prediction of in vivo adverse effects. Several HTS/HCA methods are being validated and applied for NM testing in the FP7 project NANoREG, including Label‐free cellular screening of NM uptake, HCA, High throughput flow cytometry, Impedance‐based monitoring, Multiplex analysis of secreted products, and genotoxicity methods—namely High throughput comet assay, High throughput in vitro micronucleus assay, and γH2AX assay. There are several technical challenges with HTS/HCA for NM testing, as toxicity screening needs to be coupled with characterization of NMs in exposure medium prior to the test; possible interference of NMs with HTS/HCA techniques is another concern. Advantages and challenges of HTS/HCA approaches in NM safety are discussed. WIREs Nanomed Nanobiotechnol 2017, 9:e1413. doi: 10.1002/wnan.1413For further resources related to this article, please visit the WIREs website.
a b s t r a c tThe unique properties of nanomaterials (NMs) are beneficial in numerous industrial and medical applications. However, they could also induce unintended effects. Thus, a proper strategy for toxicity testing is essential in human hazard and risk assessment. Toxicity can be tested in vivo and in vitro; in compliance with the 3Rs, alternative strategies for in vitro testing should be further developed for NMs. Robust, standardized methods are of great importance in nanotoxicology, with comprehensive material characterization and uptake as an integral part of the testing strategy. Oxidative stress has been shown to be an underlying mechanism of possible toxicity of NMs, causing both immunotoxicity and genotoxicity. For testing NMs in vitro, a battery of tests should be performed on cells of human origin, either cell lines or primary cells, in conditions as close as possible to an in vivo situation. Novel toxicity pathways, particularly epigenetic modification, should be assessed along with conventional toxicity testing methods. However, to initiate epigenetic toxicity screens for NM exposure, there is a need to better understand their adverse effects on the epigenome, to identify robust and reproducible causal links between exposure, epigenetic changes and adverse phenotypic endpoints, and to develop improved assays to monitor epigenetic toxicity.
There is serious concern about the potential harmful effects of certain nanomaterials (NMs), on account of their ability to penetrate cell membranes and the increased reactivity that results from their increased surface area compared with bulk chemicals. To assess the safety of NMs, reliable tests are needed. We have investigated the possible genotoxicity of four representative NMs, derived from titanium dioxide, zinc oxide, cerium oxide and silver, in two human cell lines, A549 alveolar epithelial cells and lymphoblastoid TK6 cells. A high-throughput version of the comet assay was used to measure DNA strand beaks (SBs) as well as oxidised purines (converted to breaks with the enzyme formamidopyrimidine DNA glycosylase). In parallel, cytotoxicity was measured with the alamarBlue® assay, and the ability of NM-treated cells to survive was assessed by their colony-forming efficiency. TiO and CeO NMs were only slightly cytotoxic by the alamarBlue® test, and had no long-term effect on colony-forming efficiency. However, both induced DNA damage at non-cytotoxic concentrations; the damage decreased from 3 to 24-h exposure, except in the case of CeO-treated A549 cells. ZnO and Ag NMs affected cell survival, and induced high levels of DNA damage at cytotoxic concentrations. At lower concentrations, there was significant damage, which tended to persist over 24 h. The implication is that all four reference metal NMs tested-whether cytotoxic or not-are genotoxic. A full assessment of NM toxicity should include tests on different cell types, different times of incubation and a wide range of (especially non-cytotoxic) concentrations; a test for cell viability should be performed in parallel. Inclusion of Fpg in the comet assay allows detection of indirect genotoxic effects via oxidative stress.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.