SUMMARYBackground: It has been reported that inhibitors of gastric acid secretion prevent bleeding after endoscopic mucosal resection for mucosal gastric neoplasm. However, uncertain whether an histamine 2 -receptor antagonist or proton-pump inhibitor is more effective. Aim: To evaluate prospectively the effectiveness of famotidine or omeprazole for ulcer management after endoscopic mucosal resection. Methods: From July 2003 to October 2004, 57 patients were randomly assigned to famotidine or omeprazole for the management of endoscopic mucosal resection. Both drugs were given intravenously for the first 2 days, thereafter by mouth. The bleeding rates after endoscopic mucosal resection, the effects on the healing of endoscopic mucosal resection-induced ulceration, and cost-benefits were compared.
A: Considerable amounts of radioactive substances (mainly 137 Cs and 134 Cs) were released into the environment after the Japanese nuclear disaster in 2011. Some restrictions on residence areas were lifted in April 2017, owing to the successive and effective decontamination operations. However, the distribution of radioactive substances in vast areas of mountain, forest and satoyama close to the city is still unknown; thus, decontamination operations in such areas are being hampered. In this paper, we report on the first aerial gamma-ray imaging of a schoolyard in Fukushima using a drone that carries a high sensitivity Compton camera. We show that the distribution of 137 Cs in regions with a diameter of several tens to a hundred meters can be imaged with a typical resolution of 2-5 m within a 10-20 min flights duration. The aerial gamma-ray images taken 10 m and 20 m above the ground are qualitatively consistent with a dose map reconstructed from the ground-based measurements using a survey meter. Although further quantification is needed for the distance and air-absorption corrections to derive in situ dose map, such an aerial drone system can reduce measurement time by a factor of ten and is suitable for place where ground-based measurement are difficult.
K: Dosimetry concepts and apparatus; Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs etc); Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators) 1Corresponding author.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.