We have reviewed a series of 56 consecutive patients treated by the Ilizarov circular fixator for various combinations of nonunion, malunion and infection of fractures. We used segmental excision, distraction osteogenesis and gradual correction of the deformity as appropriate.Treatment was effective in eliminating 40 out of 46 nonunions and all 22 infections. There were two cases of refracture some months after removal of the frame, both of which healed securely in a second frame. Correction of malunion was good in the coronal plane but there was a tendency to anterior angulation, often occurring in the regenerate bone rather than at the original fracture site, after removal of the frame. This was associated with very slow maturation of regenerate bone in some patients, occurring largely, but not exclusively, in those who smoked heavily.Patients expressed high levels of satisfaction with the outcome, despite relatively modest improvements in pain and function, presumably because their longstanding and intractable nonunion had been treated. None the less, the degree of satisfaction correlated strongly with the degree of improvement in pain and function.We emphasise the importance of a multidisciplinary team in the assessment and support of patients undergoing long and demanding treatment. The Ilizarov method is valuable, but research is needed to overcome the problems of delayed maturation of the regenerate and slow or insecure healing of the docking site.
Background Patients with Achilles tendon rupture who have non-operative treatment have traditionally been treated with immobilisation of the tendon in plaster casts for several weeks. Functional bracing is an alternative non-operative treatment that allows earlier mobilisation, but evidence on its effectiveness and safety is scarce. The aim of the UKSTAR trial was to compare functional and quality-of-life outcomes and resource use in patients treated nonoperatively with plaster cast versus functional brace. Methods UKSTAR was a pragmatic, superiority, multicentre, randomised controlled trial done at 39 hospitals in the UK. Patients (aged ≥16 years) who were being treated non-operatively for a primary Achilles tendon rupture at the participating centres were potentially eligible. The exclusion criteria were presenting more than 14 days after injury, previous rupture of the same Achilles tendon, or being unable to complete the questionnaires. Eligible participants were randomly assigned (1:1) to receive a plaster cast or functional brace using a centralised web-based system. Because the interventions were clearly visible, neither patients nor clinicians could be masked. Participants wore the intervention for 8 weeks. The primary outcome was patient-reported Achilles tendon rupture score (ATRS) at 9 months, analysed in the modified intention-to-treat population (all patients in the groups to which they were allocated, excluding participants who withdrew or died before providing any outcome data). The main safety outcome was the incidence of tendon re-rupture. Resource use was recorded from a health and personal social care perspective. The trial is registered with ISRCTN, ISRCTN62639639.
We have reviewed a series of 56 consecutive patients treated by the Ilizarov circular fixator for various combinations of nonunion, malunion and infection of fractures. We used segmental excision, distraction osteogenesis and gradual correction of the deformity as appropriate. Treatment was effective in eliminating 40 out of 46 nonunions and all 22 infections. There were two cases of refracture some months after removal of the frame, both of which healed securely in a second frame. Correction of malunion was good in the coronal plane but there was a tendency to anterior angulation, often occurring in the regenerate bone rather than at the original fracture site, after removal of the frame. This was associated with very slow maturation of regenerate bone in some patients, occurring largely, but not exclusively, in those who smoked heavily. Patients expressed high levels of satisfaction with the outcome, despite relatively modest improvements in pain and function, presumably because their longstanding and intractable nonunion had been treated. None the less, the degree of satisfaction correlated strongly with the degree of improvement in pain and function. We emphasise the importance of a multidisciplinary team in the assessment and support of patients undergoing long and demanding treatment. The Ilizarov method is valuable, but research is needed to overcome the problems of delayed maturation of the regenerate and slow or insecure healing of the docking site.
This study identified three serological features of a poor healing response in tibial shaft fractures. First, matrix collagen I and III production in the first ten weeks of healing was adequate, with evidence of significantly increased production of type III collagen. Second, there was no serological evidence of a deficient osteoblast response, as indicated by normal levels of BsALP and PICP, during this early period. Third, evidence of a deficient osteoblast response appeared only at twenty weeks after injury.
The changes observed are in keeping with previous histological work on animal fracture models, suggesting that serological measures may reflect events occurring at the fracture site and thus offer a means for noninvasive and dynamic observation of collagen synthesis after fracture. Final proof that such measurements reflect bony healing per se, as opposed to events in other tissues, would require comparison with similar data from a soft tissue injury model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.