Aim: In the United Kingdom, organ donors/recipients are screened for evidence of human T-cell leukaemia virus type-1 and type-2 (HTLV-1/2) infections. Since the United Kingdom is a low prevalence country for HTLV infections, a screening assay with high sensitivity and specificity is required. Samples with repeat reactivity on antibody testing are sent to a reference lab for confirmatory serological and molecular testing. In the case of donor screen, this leads to delays in the release of organs and can result in wastage. We aim to assess whether a signal/cut-off (S/CO) ratio higher than the manufacturer's recommendation of 1.0 in the Abbott Architect antibody assay is a reliable measure of HTLV-1/2 infection.Methods: We conducted a 5 year retrospective analysis of 7245 patients from which 11 766 samples were tested on the Abbott Architect rHTLV I/II assay. Reactive samples (S/CO >1) were referred for confirmatory serological and molecular detection (Western Blot and proviral DNA) at UK Health Security Agency, (formerly PHE, Colindale), the national reference laboratory. Electronic, protected laboratory and hospital patient databases were employed to collate data. Results: A total of 45 patients had initially reactive samples. 42.2% (n = 19/45) had an S/CO ratio > 20, with HTLV infection confirmed in n = 18/19 and indeterminate confirmatory results in n = 1/19. No samples with an S/CO ratio <4 (48.9%, n = 22/45) or 4-20 (8.9%, n = 4/45) had positive confirmatory results on subsequent confirmatory testing. Conclusion:Samples with an S/CO >20 likely represent a true HTLV-1/2 infection.Reactive samples with an S/CO <4 were unlikely to confirm for HTLV infections.Interpretation of these ratios can assist clinicians in the assessment of low reactive samples and reiterates the need for faster access to confirmatory testing.
This case report describes a 30-year-old male patient presenting with Chromobacterium violaceum cutaneous lesions who develops a subsequent bacteraemia, complicated by soft tissue and pulmonary abscesses. C. violaceum disease is a rare infection that can manifest in a spectrum from cutaneous lesions to disseminated disease and sepsis, the latter associated with high mortality. Although in the available literature there is a recommendation for a prolonged antibiotic course, we describe effective management with a shorter course of antibiotics. This case highlights the importance of not only considering a diagnosis of C. violaceum if there has been a high risk and appropriate exposure, but to also consider the changing epidemiology of the organism due to certain geographical areas becoming warmer due to climate change.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.