SummaryBackground: Exacerbation of chronic obstructive pulmonary disease (COPD) is overwhelmingly represented among patients presenting with multifocal atrial tachycardia (MAT) and has been used as a paradigm for such patients. The quasidiagnostic tachycardia threshold for MAT is conventionally set at 100 beats/min. Nevertheless, this threshold has not been demonstrated to be optimal.Hypothesis: Using COPD as a paradigm for MAT, clinical experience led to the hypothesis that MAT with a tachycardia threshold < 100 beats/min could be more closely associated with COPD exacerbation.
Methods and Results:We reviewed 60 consecutive patients with multifocal atrial arrhythmia (MAA) at any heart rate and found a better association between the incidence of COPD exacerbations and MAT using a tachycardia threshold of 90 beats/min (p = 0.00036) than when using a threshold of 100 beats/min (p = 0.515).
Conclusion:The rate threshold of MAT should be reduced from 100 to 90 beats/min.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.