The purpose of the present study was to quantify the mechanical effect of genioglossus stimulation on flow mechanics and pharyngeal cross-sectional area in patients with obstructive sleep apnoea, and to identify variables that determine the magnitude of the respiratory effect of tongue protrusion.The pressure/flow and pressure/cross-sectional area relationships of the velo-and oropharynx were assessed in spontaneously breathing propofol-anaesthetised subjects before and during genioglossus stimulation.Genioglossus contraction decreased the critical pressure significantly from 1.2¡3.3 to -0.7¡3.8 cmH 2 O, with individual decreases ranging -0.6-5.9 cmH 2 O. Pharyngeal compliance was not affected by genioglossus contraction. The pharyngeal response to genioglossus stimulation was related to the magnitude of advancement of the posterior side of the tongue, but not to the severity of sleep apnoea, critical pressure, compliance or the shape and other characteristics of the velopharynx.Genioglossus contraction enlarges both the velo-and the oropharynx and lowers the critical pressure without affecting pharyngeal stiffness. The response to genioglossus stimulation depends upon the magnitude of tongue protrusion achieved rather than on inherent characteristics of the patient and their airway.
The present study evaluated the effect of coactivation of tongue protrusors and retractors on pharyngeal patency in patients with obstructive sleep apnea. The effect of genioglossus (GG), hyoglossus (HG), and coactivation of both on nasal pressure (Pn):flow relationships was evaluated in a sleep study (SlS, n = 7) and during a propofol anesthesia study (AnS, n = 7). GG was stimulated with sublingual surface electrodes in SlS and with intramuscular electrodes in AnS, while HG was stimulated with surface electrodes in both groups. In the AnS, the cross-sectional area (CSA):Pn relationships was measured with a pharyngoscope to estimate velopharyngeal compliance . In the SlS, surface stimulation of GG had no effect on the critical pressure (Pcrit), HG increased Pcrit from 2.8 +/- 1.7 to 3.7 +/- 1.6 cmH(2)O, but coactivation lowered Pcrit to 0.2 +/- 1.9 cmH(2)O (P < 0.01 for both). In the AnS, intramuscular stimulation of GG lowered Pcrit from 2.6 +/- 1.3 to 1.0 +/- 2.8 cmH(2)O, HG increased Pcrit to 6.2 +/- 2.5 cmH(2)O (P < 0.01), and coactivation had a similar effect to that of GG (Pcrit = 1.2 +/- 2.4 cmH(2)O, P < 0.05). None of the interventions affected significantly velopharyngeal compliance. We conclude that the beneficial effect of coactivation depends on the pattern of GG fiber recruitment: although surface stimulation of GG failed to protrude the tongue, it prevented the occlusive effect of the retractor, thereby improving pharyngeal patency during coactivation. Stimulation of deeper GG fibers with intramuscular electrodes enlarged the pharynx, and coactivation had no additive effect.
The relative impact of mechanical factors on pharyngeal patency in patients with obstructive sleep apnea is poorly understood. The present study was designed to evaluate parameters of the "tube law" on pharyngeal pressure-flow relationships and collapsibility in patients with obstructive sleep apnea. We developed a mathematical model that considered the collapsible segment of the pharynx to represent an orifice of varying diameter. The model enabled us to assess the effects of pharyngeal compliance (C), neutral cross-sectional area (A(o)), external peripharyngeal pressure (P(ex)), and the resistance proximal to the site of collapse on flow mechanics and pharyngeal collapsibility [critical pressure (P(crit))]. All parameters were measured in 15 patients with obstructive sleep apnea under propofol anesthesia, both at rest and during mandibular advancement and electrical stimulation of the genioglossus. The data was used both to confirm the validity of the model and to compare expected and actual relationships between the tube-law parameters and the pharyngeal pressure-flow relationship and collapsibility. We found a close correlation between predicted and measured P(crit) (R = 0.98), including changes observed during pharyngeal manipulations. C and A(o) were closely and directly interrelated (R = 0.93) and did not correlate with P(crit). A significant correlation was found between P(ex) and P(crit) (R = 0.77; P < 0.01). We conclude that the pharynx of patients with obstructive sleep apnea can be modeled as an orifice with varying diameter. Pharyngeal compliance and A(o) are closely interrelated. Pharyngeal collapsibility depends primarily on the surrounding pressure.
Pharyngeal collapsibility during sleep is believed to increase due to a decline in dilator muscle activity. However, genioglossus electromyogram (EMG) often increases during apnoeas and hypopnoeas, often without mechanical effect.17 patients with obstructive sleep apnoea were anaesthetised and evaluated from termination of propofol administration to awakening. Genioglossus EMG, flow and pharyngeal area (pharyngoscopy) were monitored. Prolonged hypopnoeas enabled evaluation of the relationships between genioglossus EMG and mechanical events, before and after awakening. Additional dilator muscle EMGs were recorded and compared to the genioglossus. Electrical stimulation of the genioglossus was used to evaluate possible mechanical dysfunction.Prolonged hypopnoeas during inspiration before arousal triggered an increase in genioglossus EMG, reaching mean¡SD 62.2¡32.7% of maximum. This augmented activity failed to increase flow and pharyngeal area. Awakening resulted in fast pharyngeal enlargement and restoration of unobstructed flow, with marked reduction in genioglossus EMG. Electrical stimulation of the genioglossus under propofol anaesthesia increased the inspiratory pharyngeal area (from 25.1¡28 to 66.3¡75.5 mm 2 ; p,0.01) and flow (from 11.5¡6.5 to 18.6¡9.2 L?min -1 ; p,0.001), indicating adequate mechanical response. All additional dilators increased their inspiratory activity during hypopnoeas. During propofol anaesthesia, pharyngeal occlusion persists despite large increases in genioglossus EMG, in the presence of a preserved mechanical response to electrical stimulation.
AAT treatment was safe and well tolerated in pediatric subjects with recently diagnosed autoimmune diabetes. Placebo-controlled studies with larger cohorts and dose range are warranted in order to assess efficacy in maintaining pancreatic beta cell reserve and glycemic control.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.