The stability analysis of the single‐ended primary‐inductor converter DC/DC converters feeding constant power loads (CPLs) is of major importance. The nonlinear behaviour of CPLs and their negative incremental impedance, which impose adverse effects on system damping and stability margins, necessitate developing proper strategies for an efficient implementation framework of DC microgrid. In this paper, a fixed‐time sliding mode disturbance observer is first addressed to provide an estimation of the power flow moving along the uncertain CPLs with time‐varying nature within a fixed time. It not only expedites the estimation rate but also improves the robustness against physical parameter variation. The fixed‐time dynamic surface control law is then developed based on the estimated load power for the duty cycle of the switch such that the entire power grid becomes stable and the desired voltage of the DC bus is tracked within a fixed time irrespective of the initial conditions. A rigorous Lyapunov‐based approach is represented to guarantee the semi‐global fixed‐time uniform ultimate boundedness of the proposed scheme. Finally, in order to verify the proposed methodology's strengths, Model‐in‐the‐Loop real‐time simulations are performed under various operating case studies.
Nonlinear behavior of constant power loads (CPLs) and their negative incremental impedance, which impose adverse effects on system damping and stability margins, necessitate developing proper strategies for efficient implementation framework of DC microgrid. In this paper, a fixed-time sliding mode disturbance observer (SMDO) is first addressed to provide an estimation of the instantaneous power flow moving along the uncertain CPLs with time-varying nature within a fixed time.It not only expedites the estimation rate but also improves the robustness against physical parameter variation. The fast fixedtime backstepping technique is then developed based on the estimated load power to control the duty cycle of the boost converter such that the entire power grid becomes stable and the desired voltage of the DC bus is tracked within a fixed time irrespective of the initial conditions. A rigorous Lyapunov-based approach is represented to guarantee the fixed-time stability of the proposed scheme. Finally, to validate the merits and implementation feasibility of the proposed methodology, the experimental realization is represented under various operating case studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.