Glioblastoma (GBM) is the most common primary brain tumor. It is highly malignant and has a correspondingly poor prognosis. Diagnosis and monitoring are mainly accomplished with MRI, but remain challenging in some cases. Therefore, complementary methods for tumor detection and characterization would be beneficial. Using magnetic resonance elastography (MRE), we performed a longitudinal study of the biomechanical properties of intracranially implanted GBM in mice and compared the results to histopathology. The biomechanical parameters of viscoelastic modulus, shear wave speed and phase angle were significantly lower in tumors compared with healthy brain tissue and decreased over time with tumor progression. Moreover, some MRE parameters revealed sub-regions at later tumor stages, which were not easily detectable on anatomical MRI images. Comparison with histopathology showed that softer tumor regions contained necrosis and patches of viable tumor cells. In contrast, areas of densely packed tumor cells and blood vessels identified with histology coincided with higher values of viscoelastic modulus and shear wave speed. Interestingly, the phase angle was independent from these anatomical variations. In summary, MRE depicted longitudinal and morphological changes in GBM and may prove valuable for tumor characterization in patients.
Mapping neuronal activity noninvasively is a key requirement for in vivo human neuroscience. Traditional functional magnetic resonance (MR) imaging, with a temporal response of seconds, cannot measure high-level cognitive processes evolving in tens of milliseconds. To advance neuroscience, imaging of fast neuronal processes is required. Here, we show in vivo imaging of fast neuronal processes at 100-ms time scales by quantifying brain biomechanics noninvasively with MR elastography. We show brain stiffness changes of ~10% in response to repetitive electric stimulation of a mouse hind paw over two orders of frequency from 0.1 to 10 Hz. We demonstrate in mice that regional patterns of stiffness modulation are synchronous with stimulus switching and evolve with frequency. For very fast stimuli (100 ms), mechanical changes are mainly located in the thalamus, the relay location for afferent cortical input. Our results demonstrate a new methodology for noninvasively tracking brain functional activity at high speed.
Background: Anti-angiogenic treatment of glioblastoma (GBM) complicates radiologic monitoring. We evaluated magnetic resonance elastography (MRE) as an imaging tool for monitoring the efficacy of anti-VEGF treatment of GBM. Methods: Longitudinal studies were performed in an orthotopic GBM xenograft mouse model. Animals treated with B20 anti-VEGF antibody were compared to untreated controls regarding survival (n = 13), classical MRI-contrasts and biomechanics as quantified via MRE (n = 15). Imaging was performed on a 7 T small animal horizontal bore MRI scanner. MRI and MRE parameters were compared to histopathology. Results: Anti-VEGF-treated animals survived longer than untreated controls (p = 0.0011) with progressively increased tumor volume in controls (p = 0.0001). MRE parameters viscoelasticity |G*| and phase angle Y significantly decreased in controls (p = 0.02 for |G*| and p = 0.0071 for Y). This indicates that untreated tumors became softer and more elastic than viscous with progression. Tumor volume in treated animals increased more slowly than in controls, indicating efficacy of the therapy, reaching significance only at the last time point (p = 0.02). Viscoelasticity and phase angle Y tended to decrease throughout therapy, similar as for control animals. However, in treated animals, the decrease in phase angle Y was significantly attenuated and reached statistical significance at the last time point (p = 0.04). Histopathologically, control tumors were larger and more heterogeneous than treated tumors. Vasculature was normalized in treated tumors compared with controls, which showed abnormal vasculature and necrosis. In treated tumors, a higher amount of myelin was observed within the tumor area (p = 0.03), likely due to increased tumor invasion. Stiffness of the contralateral hemisphere was influenced by tumor mass effect and edema.
Evaluate changes in the shear modulus of brain tissue as a new measure of localized brain function. A spin-echo magnetic resonance elastography (MRE) sequence was modified to allow two interleaved paradigms: stimulus ON/OFF. To avoid neuronal habituation, a paradigm was active for 9s before switching to the other paradigm. After each paradigm switch, a period of 1.8 s was allowed for hemodynamic equilibrium. Seven healthy black mice were studied. An electrical current to the hind limb, ~1 mA, 3 Hz, pulse width ~250 ms, was used as the functional stimulus. A separate control scan was also performed where no stimulus was applied for either paradigm. Vibration frequency = 1kHz. In six of the seven animals, a localized increase in G’ was observed in the somatosensory and motor cortex areas, whereas no difference was observed in the control scan. The average increase of G’ = 14%. Two potential mechanisms were considered: (i) a vascular effect similar to BOLD in fMRI and (ii) calcium influx into the neurons. The first mechanism was ruled out based on results from an additional experiment where hypercapnia was induced to cause vasodilation. This implies the mechanism responsible is a primary measure of neuronal activation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.