In this study we propose the use of a natural indicator obtained from the seeds of plant found abundantly in the southern of Bahia, Brazil, Theobroma cacao L. (cocoa). The extract containing the dyes from cocoa seed was applied as indicator in several acid/base titrations, and the results were compared with values obtained in potentiometric titrations and using phenolphthalein as an indicator of reference. The methodologies involving weak and strong acids were applied with chemistry graduate students of
Experimental design is an important chemometric tool for systemic optimization, allowing the study of a number of variables concomitantly, thus reducing the number of tests, time and reagents that are used in addition to reduce the amount of generated residues. In the present work the main objective was to use a factorial design 2 2 with central and axial points for optimization of cloud point extraction in order to determine cadmium, nickel, lead and cobalt by flame atomic absorption spectrometry. Variables that were studied in this factorial design were the amount of complexing agent, ammonium pyrrolidine dithiocarbamate (APDC) and the amount of surfactant (Triton X-100). Analysis of the math models that were developed from the design experiments demonstrated that in the case of nickel and cobalt these variables did not contributed significantly to increase absorbance readings. On the other hand, in the determination of cadmium the results have shown that it is necessary to reduce the amount of complexing agent, and for lead, it was shown to be necessary to increase both the amounts of complexing agent and surfactant. After optimization, the cloud point extraction was carried out using eye makeup samples, which presented concentrations for nickel and lead within 4.96 and 14.03 x 10 1 mg.kg-1. These values are within the allowed range of the Agência Nacional de Vigilância Sanitária (ANVISA), which establishes the limits of 20 mg.kg-1 and 100 mg.kg-1 respectively for lead and other metals in artificial organic dyes for cosmetics. Although the samples studied here have shown to be in a concentration range that would exempt them from a pre-concentration step, considering the analysis by atomic absorption spectrometry, the use of cloud point extraction has shown to be effective and also recommended in cases in which the analyzed metals are present in trace amounts.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.