Background:The increasing number of mobile phones can physically cause electromagnetic interference (EMI) in medical environments; can also cause errors in immunoassays in laboratories. The ELISA readers are widely used as a useful diagnostic tool for Enzymun colorimetric assay in medicine. The aim of this study was to investigate whether the ELISA reader could be interfered by the exposure to the 900 MHz cell phones in the laboratory.Materials and Methods:Human serum samples were collected from 14 healthy donors (9 women and 5 men) and each sample was divided into four aliquots and was placed into four batches for the in-vitro quantitative determination of human chorionic gonadotropin (hCG). During colorimetric reading of the first, second, and third batches, the ELISA reader (Stat Fax 2100, Awareness Technology, Inc., USA) was exposed to 0.5, 1.0, and 2.0 W exposure of 900 MHz radiation, respectively. For the forth batch (control group), no radiation was applied. All experiments were performed comparing ELISA read out results of the I, II, and III batches with the control batch, using the Wilcoxon test with criterion level of P = 0.050.Results:The final scores in the exposed batches I, II, and III were not statistically significant relative to the control batch (P > 0.05). The results showed that 900 MHz radiation exposure did not alter the ELISA measured levels of hCG hormone in I (P = 0.219), II (P = 0.909), and III (P = 0.056) batches compared to the control batch.Conclusion:This study showed that ELISA reader does not interfere by mobile phone RF radiation at a closed contact (less than 5 cm distance). However, we recommend that medical institutions discuss these issues in the context of their specific use of technologies and frame a policy that is clear and straightforward to guide staff, patients, and visitors.
Background: The aim of this study was to design an algorithm for the calculation of monitor unit (MU) in a short time and high precision for different radiotherapy (RT) fields. Materials and Methods: The algorithm for calculating MU for the stated patients was designed in MATLAB software. To investigate the efficiency of this algorithm, 11 regular chest fields with the sizes of 7 cm × 7 cm up to 17 cm × 17 cm were considered, and the obtained MUs were compared with MUs of 13 patients which were calculated with a “hand calculation” which is used in some RT centers for the aforementioned fields. Results: The maximum percentage of calculation errors of regular fields at the depths of 4 and 10 cm were 1 and 0.8, respectively. The maximum and minimum percentage of calculation errors in irregular fields was 3 and 0.9, respectively. Furthermore, the maximum and minimum errors were 8.8 and 0.14, respectively. In addition, relative percentages of the MUs for irregular fields of chest and supraclavicular were 1.63 and 1.01, respectively. Conclusion: Calculation of MUs is suggested to be performed with the novel proposed algorithm, due to reduce the treatment time, and also provide high accuracy and precision compared to hand calculation.
The aim of radiotherapy is to deliver the highest possible radiation dose to the tumor and the lowest radiation to normal tissues surrounding the tumor. In the present study, lymph nodes of the supraclavicular region were treated using two therapeutic techniques, namely photon technique (PT) and combinatory photon-electron technique (CPET). We recruited 50 patients with local lymph node metastasis. The photon energies were 6-15 MV. Furthermore, the electron beam energy was 18 MeV in CPET. The study findings revealed that the mean delivered dose to target volume was 41.12 ± 2.98Gy for PT and 44.56 ± 1.90Gy for CPET. The percentage of the target volume irradiated to 90% of the prescribed dose (V90) was calculated as 74.61% ± 9.30% and 82.06% ± 9.70% for PT and CPET, respectively. The mean dose delivered to the heart and lungs was not significantly different between the two groups. Furthermore, the maximum doses delivered to the spinal cord were 12.55Gy in PT and 8.89Gy in CPET. The mean doses delivered to the thyroid gland were 39.26 and 34.89Gy in PT and CPET. According to the study results, the maximum doses delivered to the spinal cord, head of the humerus bone, and thyroid were reduced significantly as measured the CPET technique. In contrast, no significant difference was observed regarding the dose delivered to the heart and lung. The dose delivered to the supraclavicular region determined by the CPET was significantly augmented. Furthermore, the coverage of the tumor mass was optimized using the new method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.