This study demonstrates that the use of aCGH as a first line test is able to identify chromosomal mosaicism down to 9%, which is lower than the level reliably detected using standard cytogenetic analysis. aCGH avoids the disadvantages of culturing, which include culture bias, artifact, and culture failure.
Key Clinical messageCase report involving a normal female by NIPT with male external genitalia on routine fetal morphology assessment. QF-PCR, CGH microarray, and FISH revealed an unbalanced translocation, involving the short arms of the X and Y chromosomes. This case demonstrates the possible limitations of correctly identifying sex chromosome abnormalities via NIPT.
Short oral presentation abstractsSupporting information can be found in the online version of this abstract OP17.07 Development of auditable standards in the first trimester ultrasound assessment of fetal blood flow through the ductus venosus and the tricuspid valve Objectives: To develop reference ranges for the ductus venosus (DV) and tricuspid valve (TV) waveforms at 11-14 weeks to define auditable standards to assess operator measurement performance. Methods: A single operator utilising the FMF criteria, prospectively obtained quantitative measurements for DV (pulsatility index for veins [PIV], pre-load index [PLI] and peak velocity for veins [PVIV]) and TV (E-wave peak velocity [EWPV], A-wave peak velocity [AWPV] and E-A ratio) to develop medians and 90% reference intervals. Measurement agreement studies between two experienced operators were also performed. The measurement bias of 3 additional operators was subsequently assessed using these auditable standards. Results: Doppler measurements were obtained in 292 patients (DV) and 321 patients (TV). Highly correlated DV indices indicated that only one reference range (for PIV) was necessary with a mean PIV measurement of 1.06 (90% RI 0.86 -1.23). As both EWPV and AWPV changed reliably over gestation, only the E-A ratio reference range was computed.Intra-observer and inter-observer studies on 30 additional patients of the DV PI and TV E-A ratio showed the within-operator agreement was almost perfect for DV PIV (ICC 0.82 -0.86) and strong for TV E-A ratio (ICC 0.68 -0.78) whilst the betweenoperator agreement was good for both DV PIV and TV E-A ratio measurements (ICC 0.46 for both).Preliminary audit using central tendency and dispersion of the measurements by 3 trained operators showed a tendency to overestimate DV PI (0.97, 1.07 and 1.09 MoM respectively; SD log PI 0.03-0.06) whilst the TV E-A ratio distribution met expectation (0.97, 0.98 and 0.98 MoM respectively; SD log E-A ratio 0.04 -0.1). Conclusions: Measurements of DV PIV and TV E-A ratio by experienced operators were found to be reproducible. Development of local reference ranges enabled the definition of quantitative auditable standards that can be utilized in assessment of operator training and ongoing Doppler measurement quality assurance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.