Methods are needed for quantifying the potency and differential effects of risk factors to identify at-risk groups for theory building and intervention. Traditional methods for constructing war exposure measures are poorly suited to "unpack" differential relations between specific types of exposure and specific outcomes. This study of 881 Bosnian adolescents compared both common factor-effect indicator (using exploratory factor analysis) versus composite causal-indicator methods for "unpacking" dimensions of war exposure and their respective paths to postwar adjustment outcomes. The composite method better supported theory building and most intervention applications, showing how multitiered interventions can enhance treatment effectiveness and efficiency in war settings. Used together, the methods may unpack the elements and differential effects of "caravans" of risk and promotive factors that co-occur across development.
Fluoride release is important characteristic of glass-ionomer cements. Quantity of fluoride ions released from the glass-ionomer cements has major importance in definition of their biological activity. The objectives of this study were to define the quantity of fluoride ions released from the experimental glass-ionomer cements and to define the effect of fluoride ions released from the experimental glass-ionomer cements on their cytotoxicity. Concentrations of the fluoride ions released in the evaluated glass-ionomer cements were measured indirectly, by the fluoride-selective WTW, F500 electrode potential, combined with reference R503/D electrode. Statistical analyses of F-ion concentrations released by all glass-ionomers evaluated at two time points, after 8 and after 24 hours, show statistically higher fluoride releases from RMGICs: Vitrebond, Fuji II LC and Fuji Plus, when compared to conventional glass-ionomer cements: Fuji Triage, Fuji IX GP Fast and Ketac Silver, both after 8 and after 24 hours. Correlation coefficient between concentrations of fluoride ion released by evaluated glass-ionomer cements and cytotoxic response of UMR-106 osteoblast cell-line are relatively high, but do not reach levels of biological significance. Correlation between concentrations of fluoride ion released and cytotoxic response of NIH3T3 mouse fibroblast cell line after 8 hours is high, positive and statistically significant for conventional GICs, Fuji Triage and Fuji IX GP Fast, and RMGIC, Fuji II LC. Statistically significant Correlation coefficient between concentrations of fluoride ion released and cytotoxic response of NIH3T3 cell line after 24 hours is defined for RMGIC Fuji II LC only.
The study examined the psychometric characteristics of three automated working memory span tasks: operational, reading, and symmetry span task, administered in groups of participants. For each task, the metric characteristics of six scoring procedures were evaluated: partial, absolute, partial non-weighted, absolute non-weighted, partial weighted, and absolute weighted scoring. Metric characteristics of all measures were compared across two parallel analyses: with and without application of a typical 85% accuracy criterion on the processing component of the tasks. The study demonstrates that the group administration of span tasks does not compromise their psychometric characteristics. All the tasks had an adequate internal consistency with Cronbach’s αs equal to or above .70; the exception being all types of the symmetry span task absolute scores with α values close to .60. Furthermore, all tasks have satisfactory convergent construct validity as well as criterion validity estimated in relation to measures of fluid intelligence. Omitting the 85% accuracy criterion on the processing component of the span tasks did not impair their psychometric properties. Thus, it is recommended that researchers discard this accuracy criterion as a criterion for filtering the results for further statistical analyses.
The aims of this study were to assess the factor structure of a new instrument for the measurement of intrinsic, extraneous and germane cognitive load in a Bosnian sample, to determine the internal consistency of this instrument and to determine whether the instrument predicts learning outcomes. The participants were 75 undergraduate students from the Department of Psychology, University of Sarajevo. Data was collected using the Questionnaire for the Measurement of Intrinsic, Extraneous and Germane Load developed by Leppink, Pass, Van der Vleuten, Van Gog & Van Merrienboer [15] and a Brief Test of Knowledge developed for the purpose of the present study. Results of a confirmatory factor analysis support a three-dimensional model, with the item loadings in the expected manner. The factor structure obtained in our study is consistent with the factor structure reported by Leppink et al. [15]. In addition, the scale items showed good internal consistencies. The results obtained in our study suggest that low intrinsic in combination with high germane scores contribute to learning outcome. High complexity of learning material in combination with not well-organized prerequisite knowledge causes lower investment of germane cognitive resources, i.e. learning process, and consequently lower learning outcome. Overall, despite a relatively small sample size, the results of our study show a clear three-factor structure that corresponded to intrinsic, extraneous and germane cognitive load. The questionnaire could be an important instrument for research practice in domain of CLT. Moreover, the instrument has significant practical value. Educational practitioner can use the instrument in researching and planning their teaching to maximise learning.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.