(1) Background: Chronic diseases affect patients’ quality of life. Age Macular Degeneration (AMD) is one of the most prevalent chronic ocular diseases. The study aims to measure the anxiety and quality of life related to vision in patients with AMD, as well as the relationship with other visual and demographic parameters. (2) Methods: Prospective cross-sectional study in AMD patients. Visual acuity (VA), contrast sensitivity (CS), line difference in the Colenbrander test, and the degree of pathology were measured. Other variables such as gender, age, and time from the diagnosis were also collected. Anxiety was measured with the Spielberger State-Trait Anxiety Inventory (STAI) and quality of life with the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) checklist was followed. (3) Results: Patients with higher punctuation in Trait STAI showed lower punctuation in NEI VFQ-25 questionnaire (Spearman coefficient −0.415; p = 0.001). The variables VA, CS, and age were correlated to the quality of life. The relationship between trait anxiety and subscales of NEI VFQ-25 was significant for all subscales (p < 0.05), except for social functioning, peripheral vision, general vision, ocular pain, and driving. (4) Conclusions: AMD patients with higher levels of anxiety show a decrease in their quality of life. The quality of life of AMD patients depends on their VA and CS.
Background: Age-related macular degeneration (AMD) is a disease with an increasing incidence due to the general aging of the population that decreases the patient’s quality of life. This work aims to study whether selective cut optical filters improve the AMD patient’s quality of life. Methods: Prospective and longitudinal study in 79 patients. Visual acuity, contrast sensitivity, and the line differences in the Colenbrander test were measured. Patients answered The National Eye Institute 25-Item Visual Function Questionnaire (NEI VFQ-25), which measures the quality of life related to vision before and after using cut optical filters. Results: There was an improvement of 5.99 points (3.7–8.3) in NEI VFQ-25 after wearing filters. This improvement was 4.0 points for 450-nm filters and 12.7 points for 511-nm filters. For patients with visual acuity (VA) < 0.25, results of NEI VFQ-25 increased by 10.11 points (1.19–19.02) and for patients with late AMDs, results increased by 5.33 points (1.31–9.35). Conclusions: Selective filters improve the quality of life of patients with AMD. The success rate in the fitting of filters is better for those with VA lower than 0.25 and those with late or advanced AMD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.