The portable test system is a rapid, simple, and accurate technique using the quantitative kinetic chromogenic method for bacterial endotoxin determination. For this reason, the test is practical for radiopharmaceutical uses and tends to be the method of choice for the pyrogen test. For (18)F-FDG, (99m)Tc, MDP, and pyrophosphate, the validation was successfully performed.
À Dra. Constancia Pagano Gonçalves da Silva, mulher valorosa, excelente profissional, pioneira no desenvolvimento da Radiofarmácia no Brasil e minha orientadora, pela convivência harmoniosa, pelos ensinamentos, pelo exemplo de vida, conselhos, apoio e confiança em mim depositados contribuindo para o meu crescimento pessoal e profissional. À Dra. Nilda Petrona Sosa de Pereira, minha amiga, pelo apoio, pelo incentivo, pela paciência, por me conduzir nos primeiros passos da radiofarmácia, pelos ensinamentos, conselhos e maravilhosas experiências de vida transmitidos.Ao MSc. Jair Mengatti, gerente do Centro de Radiofarmácia do IPEN-CNEN/SP, pelo inestimável apoio e colaboração. À Dra. Margareth Mie Nakamura Matsuda, pelos conselhos, ensinamentos e colaboração durante a execução do trabalho.À querida Adriana Vidal Fernandes pelo inestimável apoio, carinho e colaboração na parte experimental e análise estatística. Aos funcionários do Centro de Radiofármacia, especialmente Domingos Gomes deCampos e Natanael Gomes da Silva, que muito contribuíram na realização deste trabalho, A todos os colegas e professores das disciplinas de pós-graduação do IPEN, pelo agradável convívio, incentivo, amizade e conhecimentos adquiridos.À Luzia de Fatima Pereira, funcionária da Alko do Brasil, fornecedora da maior parte do material utilizado nos experimentos, pelo inestimável apoio e colaboração.À minha querida família, pelo amor, compreensão e encorajamento em todos os momentos de minha vida."...se buscares a sabedoria como a prata e como a tesouros escondidos a procurares, então, entenderás o temor do Senhor e acharás o conhecimento Para estabelecer evidência documentada, que proporcione com alto grau de segurança, de que determinado procedimento quando executado sob condições pré-estudadas e definidas seja capaz de reproduzir um serviço ou bem dentro das especificações e qualidade desejáveis, as BPF recomendam que seja realizada a validação dos processos e das metodologias analíticas. É parte integrante do Sistema de Qualidade e tem por escopo a confiabilidade dos processos e sistemas. DETERMINATION OF BACTERIAL ENDOTOXIN (PYROGEN) IN[1,4] RadiofármacosTodo produto a ser administrado em humanos deve reunir requisitos de qualidade, segurança e eficácia. Os radiofármacos devem cumprir os requisitos exigidos aos produtos farmacêuticos convencionais, como as BPF e ainda outros específicos, por se tratarem de substâncias radioativas.[5]Radiofármaco é um medicamento especial ou produto que, quando pronto para uso, contém um radioisótopo em sua constituição e é utilizado em seres humanos para o diagnóstico e tratamento de enfermidades. [6,7] Com uma filosofia similar, as Boas Práticas O radiofármaco deve ser seguro e não tóxico para administração em humanos, as radiações emitidas pelo radioisótopo devem ser facilmente detectadas por instrumentos adequados e a dose de radiação ao paciente deve ser mínima. [7] Os radioisótopos utilizados em medicina nuclear são na sua maioria, artificiais e são produzidos principalmente em ciclotron ou reator...
The aim of this work was to develop a selective method for quantification of Sn(II) and Sn(IV) in dimercaptosuccinic acid (DMSA), ethylcysteinate dimer (ECD), methylenediphosphonic acid (MDP), and pyrophosphate radiopharmaceutical cold kits by differential pulse polarography. Methods: A dripping mercury electrode 150 polarographic/stripping analyzer with a conventional 3-electrode configuration was used with 3 M H 2 SO 4 and 3 M HCl supporting electrolytes for Sn(II) and Sn(IV), respectively. The polarographic analysis was performed using a 1-s drop time, 50-mVÁs 21 scan rate, 250-mV pulse amplitude, 40-ms pulse time, and 10-mV step amplitude. To quantify Sn(IV), oxidation of Sn(II) by H 2 O 2 was performed. The calibration curves for Sn (II) and Sn(IV) were obtained in the range of 0-10 mgÁmL 21 . Results: The analytic curves for Sn(II) in 3 M H 2 SO 4 and Sn(IV) in 3 M HCl were represented by the following equations: i (mA) 5 0.098 [Sn(II)] 1 0.018 (r 2 5 0.998) and i (mA) 5 0.092 [Sn(IV)] 1 0.016 (r 2 5 0.998), respectively. The detection limits were 0.21 mgÁmL 21 for Sn(II) and 0.15 mgÁmL 21 for Sn(IV). In DMSA, ECD, MDP, and pyrophosphate, 90.0%, 64.9%, 93.2%, and 87.5%, respectively, of the tin was present as Sn(II). In this work, selective determination of Sn(II) and Sn(IV) was achieved using 2 supporting electrolytes (H 2 SO 4 and HCl). In 3 M H 2 SO 4 , only Sn(II) produced a polarographic wave with the maximum current in 2370 mV. Under the same conditions, no current could be determined for Sn(IV). In 3 M HCl, Sn(II) and Sn(IV) were electroactive and the maximum currents of the 2 waves appeared in 2250 and 2470 mV. No other components of the lyophilized reagents had any influence. Conclusion: The developed polarographic method was adequate to quantify Sn(II) and Sn(IV) in DMSA, ECD, MDP, and pyrophosphate cold kits. Radi opharmaceutical cold kits for labeling with 99m Tc contain Sn(II) for reduction of technetium to lower oxidation states that are chemically reactive to specific ligands. Besides these ligands, the cold kits usually contain stannous chloride (SnCl 2 ) and different additives (complexing agents, antioxidants, and buffers). The amount of stannous ions varies (0.03-1.5 mg of SnCl 2 ), although a minimum concentration must be present to guarantee the lyophilized reagent shelf life and to allow efficient labeling with 99m Tc (1).Depending on the medium composition, Sn(II) ions in low-concentration solutions (,2.0Á10 24 M) are oxidized, and the formation of basic complexes takes place above pH 2.00 (2,3). The quantitative determination of Sn(II) in radiopharmaceutical cold kits is an important aspect of quality control, and the analytic method must be accurate even in the presence of Sn(IV) ions (4).Such techniques as colorimetry, titrimetry, spectrophotometry, voltammetry, and polarography have been described in the literature for Sn(II) determination in cold kits (5-12).Zimmer et al. studied the formation of a red porphyrin complex in the presence of Sn(II) ions using a colorimetric method....
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.