Inhomogeneous exposures to ionizing radiation can be detected and quantified with the Dicentric Chromosome Assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole body irradiation has significantly improved throughput without compromising accuracy, however low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial body exposure determination. Materials and Methods: We describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration samples and those exposed to unknown radiation levels are corrected subtracting this false positive fraction from each. In partial body exposures, the fraction of cells exposed, and radiation dose can be quantified after applying this modification of the contaminated Poisson method. Results: Dose estimates of three partially irradiated samples diverged 0.2 to 2.5 Gy from physical doses and irradiated cell fractions deviated by 2.3-15.8% from the known levels. Synthetic partial body samples comprised of unirradiated and 3 Gy samples from 4 laboratories were correctly discriminated as inhomogeneous by multiple criteria. Root mean squared errors of these dose estimates ranged from 0.52 to 1.14 Gy 2 and from 8.1 to 33.3% 2 for the fraction of cells irradiated. Conclusions: Automated DCA can differentiate whole-from partial-body radiation exposures and provides timely quantification of estimated whole-body equivalent dose. .
After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0–1 Gy), moderately (1–2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semi-automatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.
The present results established for the first time the radioprotective activity of curcumin-encapsulated liposomes in human blood cells, which coupled by its well-established bioavailability, boded well for its potential application as a nanoscale delivery system of other radioprotective phytochemicals.
The dicentric chromosome (DC) assay accurately quantifies exposure to radiation; however, manual and semi-automated assignment of DCs has limited its use for a potential large-scale radiation incident. The Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates unattended DC detection and determines radiation exposures, fulfilling IAEA criteria for triage biodosimetry. This study evaluates the throughput of high-performance ADCI (ADCI-HT) to stratify exposures of populations in 15 simulated population scale radiation exposures. ADCI-HT streamlines dose estimation using a supercomputer by optimal hierarchical scheduling of DC detection for varying numbers of samples and metaphase cell images in parallel on multiple processors. We evaluated processing times and accuracy of estimated exposures across census-defined populations. Image processing of 1744 samples on 16,384 CPUs required 1 h 11 min 23 s and radiation dose estimation based on DC frequencies required 32 sec. Processing of 40,000 samples at 10 exposures from five laboratories required 25 h and met IAEA criteria (dose estimates were within 0.5 Gy; median = 0.07). Geostatistically interpolated radiation exposure contours of simulated nuclear incidents were defined by samples exposed to clinically relevant exposure levels (1 and 2 Gy). Analysis of all exposed individuals with ADCI-HT required 0.6–7.4 days, depending on the population density of the simulation.
The goal of the RENEB inter-laboratory comparison 2021 exercise was to simulate a large-scale radiation accident involving a network of biodosimetry labs. Labs were required to perform their analyses using different biodosimetric assays in triage mode scoring and to rapidly report estimated radiation doses to the organizing institution. This article reports the results obtained with the cytokinesis-block micronucleus assay. Three test samples were exposed to blinded doses of 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 13 mA, ∼75 keV, 1 Gy/min). These doses belong to 3 triage categories of clinical relevance: a low dose category, for no exposure or exposures inferior to 1 Gy, requiring no direct treatment of subjects; a medium dose category, with doses ranging from 1 to 2 Gy, and a high dose category, after exposure to doses higher than 2 Gy, with the two latter requiring increasing medical attention. After irradiation the test samples (no. 1, no. 2 and no. 3) were sent by the organizing laboratory to 14 centers participating in the micronucleus assay exercise. Laboratories were asked to setup micronucleus cultures and to perform the micronucleus assay in triage mode, scoring 500 binucleated cells manually, or 1,000 binucleated cells in automated/semi-automated mode. One laboratory received no blood samples, but scored pictures from another lab. Based on their calibration curves, laboratories had to provide estimates of the administered doses. The accuracy of the reported dose estimates was further analyzed by the micronucleus assay lead. The micronucleus assay allowed classification of samples in the corresponding clinical triage categories (low, medium, high dose category) in 88% of cases (manual scoring, 88%; semi-automated scoring, 100%; automated scoring, 73%). Agreement between scoring laboratories, assessed by calculating the Fleiss' kappa, was excellent (100%) for semi-automated scoring, good (83%) for manual scoring and poor (53%) for fully automated scoring. Correct classification into triage scoring dose intervals (reference dose ±0.5 Gy for doses ≤2.5 Gy, or reference dose ±1 Gy for doses >2.5 Gy), recommended for triage biodosimetry, was obtained in 79% of cases (manual scoring, 73%; semi-automated scoring, 100%; automated scoring, 67%). The percentage of dose estimates whose 95% confidence intervals included the reference dose was 58% (manual scoring, 48%; semi-automated scoring, 72%; automated scoring, 60%). For the irradiated samples no. 2 and no. 3, a systematic shift towards higher dose estimations was observed. This was also noticed with the other cytogenetic assays in this intercomparison exercise. Accuracy of the rapid triage modality could be maintained when the number of manually scored cells was scaled down to 200 binucleated cells. In conclusion, the micronucleus assay, preferably performed in a semi-automated or manual scoring mode, is a reliable technique to perform rapid biodosimetry analysis in large-scale radiation emergencies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.