The methodology proposed in this study for extending fatigue life and increasing stiffness of locking plates can potentially be extended to any locking plate. Adding a screw head or screw heads to open holes in locking plates adds little additional time or expense and no morbidity to the procedure but can have substantial effects on the mechanical properties of the implant, particularly in lower-profile plates that are initially less rigid and robust.
OBJECTIVEIn this study, the authors’ goal was to determine the intra- and interobserver reliability of a new classification system that allows the description of all possible constructs used across three-column osteotomies (3COs) in terms of rod configuration and density.METHODSThirty-five patients with multirod constructs (MRCs) across a 3CO were classified by two spinal surgery fellows according to the new system, and then were reclassified 2 weeks later. Constructs were classified as follows: the number of rods across the osteotomy site followed by a letter corresponding to the type of rod configuration: “M” is for a main rod configuration, defined as a single rod spanning the osteotomy. “L” is for linked rod configurations, defined as 2 rods directly connected to each other at the osteotomy site. “S” is for satellite rod configurations, which were defined as a short rod independent of the main rod with anchors above and below the 3CO. “A” is for accessory rods, defined as an additional rod across the 3CO attached to main rods but not attached to any anchors across the osteotomy site. “I” is for intercalary rod configurations, defined as a rod connecting 2 separate constructs across the 3CO, without the intercalary rod itself attached to any anchors across the osteotomy site. The intra- and interobserver reliability of this classification system was determined.RESULTSA sample estimation for validation assuming two readers and 35 subjects results in a two-sided 95% confidence interval with a width of 0.19 and a kappa value of 0.8 (SD 0.3). The Fleiss kappa coefficient (κ) was used to calculate the degree of agreement between interrater and intraobserver reliability. The interrater kappa coefficient was 0.3, and the intrarater kappa coefficient was 0.63 (good reliability). This scenario represents a high degree of agreement despite a low kappa coefficient. Correct observations by both observers were 34 of 35 and 33 of 35 at both time points. Misclassification was related to difficulty in determining connectors versus anchors.CONCLUSIONSMRCs across 3COs have variable rod configurations. Currently, no classification system or agreement on nomenclature exists to define the configuration of rods across 3COs. The authors present a new, comprehensive MRC classification system with good inter- and intraobserver reliability and a high degree of agreement that allows for a standardized description of MRCs across 3COs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.