ObjectivesTo determine risk factors for revision in patients implanted with a commonly used metal on metal (MoM) hip replacement.DesignRetrospective cohort study in combination with a prospective national retrieval study (Northern Retrieval Registry (NRR)).SettingCombined orthopaedic unit in combination with the NRR.ParticipantsAll patients implanted with a DePuy Pinnacle MoM hip prostheses by the 2 senior authors were invited to attend for a review which included clinical examination, blood metal ion measurements, radiographs and targeted imaging. Explanted components underwent wear analysis using validated methodology and these results were compared with those obtained from the NRR.Results489 MoM Pinnacle hips were implanted into 434 patients (243 females and 191 males). Of these, 352 patients attended the MoM recall clinics. 64 patients had died during the study period. For the purposes of survival analysis, non-attendees were assumed to have well-functioning prostheses. The mean follow-up of the cohort as a whole was 89 months. 71 hips were revised. Prosthetic survival for the whole cohort was 83.6% (79.9–87.3) at 9 years. The majority of explanted devices exhibited signs of taper junction failure. Risk factors for revision were bilateral MoM prostheses, smaller Pinnacle liners, and implantation in 2006 and later years. A significant number of devices were found to be manufactured out of their specifications. This was confirmed with analysis of the wider data set from the NRR.ConclusionsThis device was found to have an unacceptably high revision rate. Bilateral prostheses, those implanted into female patients and devices implanted in later years were found to be at greater risk. A significant number of explanted components were found to be manufactured with bearing diameters outside of the manufacturer's stated tolerances. Our findings highlight the clinical importance of hitherto unrecognised variations in device production.
The purpose of this study was to investigate the effects of right leg restriction at the knee, ankle or both, on a driver's braking times. Previous studies have not investigated the effects of knee restriction on braking performance. A total of 23 healthy drivers performed a series of emergency braking tests in a driving simulator in either an above-knee plaster cast, a below-knee cast, or in a knee brace with an increasing range of restriction. The study showed that total braking reaction time was significantly longer when wearing an above-knee plaster cast, a below-knee plaster cast or a knee brace fixed at 0°, compared with braking normally (p < 0.001). Increases in the time taken to move the foot from the accelerator to the brake accounted for some of the increase in the total braking reaction time. Unexpectedly, thinking time also increased with the level of restriction (p < 0.001). The increase in braking time with an above-knee plaster cast in this study would increase the stopping distance at 30 miles per hour by almost 3 m. These results suggest that all patients wearing any lower-limb plaster cast or knee brace are significantly impaired in their ability to perform an emergency stop. We suggest changes to the legislation to prevent patients from driving with lower-limb plaster casts or knee braces.
This study shows evidence that previously unappreciated variations in manufacturing processes may have a major impact on the clinical outcomes of patients.
Background Resurfacing is a popular alternative to a standard hip replacement in young arthritic patients. Despite bone preservation around the femoral component, there is little information regarding the bone quality.Patients and methods 32 patients underwent consecutive Birmingham hip resurfacing. The bone density of the femoral neck was measured preoperatively and then at 6 weeks, 3 months, 1 year, and 2 years. The femoral neck was divided into regions of interest. Results were available for 27 hips in 26 patients.Results The overall femoral neck bone density showed a trend towards a decrease at 6 weeks and 3 months but returned to the preoperative level at 1 year, and was maintained at 2 years. The combined superior regions of the neck showed a statistically significant decrease in bone density at 6 weeks and 3 months. This returned to preoperative levels at 1 year and was maintained at 2 years.Interpretation Bone density appears to decrease at 6 weeks and 3 months, suggesting that care is necessary until bone density begins to recover.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.