Whole-cell bacterial bioreporters await miniaturized photon counting modules with high sensitivity and robust compatible hardware to fulfill their promise of versatile, on-site biosensor functionality. In this study, we explore the photon counting readout properties of the silicon photomultiplier (SPM) with a thermoelectric cooler and the possibilities of detecting low-level bioluminescent signals. Detection performance was evaluated through a simulated LED light source and the bioluminescence produced by the genetically engineered Pseudomonas fluorescens bacterial bioreporter 5RL. Compared with the conventional photomultiplier tube (PMT), the results revealed that the cooled SPM exhibits a wider linear response to inducible substrate concentrations (salicylate) ranging from 250 to 5000 ppb. Although cooling of the SPM lowered dark count rates and improved the minimum detectable signal, and the application of a digital filter enhanced the signal-to-noise ratio, the detection of very low light signals is still limited and remains a challenge in the design of compact photon counting systems.
The focus of this research effort was to develop an autonomous, inducible, lux-based bioluminescent bioreporter for the real-time detection of dichloromethane. Dichloromethane (DCM), also known as methylene chloride, is a volatile organic compound and one of the most commonly used halogenated solvents in the U.S., with applications ranging from grease and paint stripping to aerosol propellants and pharmaceutical tablet coatings. Predictably, it is released into the environment where it contaminates air and water resources. Due to its classification as a probable human carcinogen, hepatic toxin, and central nervous system effector, DCM must be carefully monitored and controlled. Methods for DCM detection usually rely on analytical techniques such as solid-phase microextraction (SPME) and capillary gas chromatography or photoacoustic environmental monitors, all of which require trained personnel and/or expensive equipment. To complement conventional monitoring practices, we have created a bioreporter for the self-directed detection of DCM by taking advantage of the evolutionary adaptation of bacteria to recognize and metabolize chemical agents. This bioreporter, Methylobacterium extorquens DCM( lux ), was engineered to contain a bioluminescent luxCDABE gene cassette derived from Photorhabdus luminescens fused downstream to the dcm dehalogenase operon, which causes the organism to generate visible light when exposed to DCM. We have demonstrated detection limits down to 1.0 ppm under vapor phase exposures and 0.1 ppm under liquid phase exposures with response times of 2.3 and 1.3 h, respectively, and with specificity towards DCM under relevant industrial environmental monitoring conditions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.