We present a fully automatic method, autoP, for identification and quantification of lipids in complex lipid mixtures from 1D (31)P and 2D (1)H-(31)P NMR spectra. The (31)P chemical shifts in lipids are highly sensitive to experimental conditions such as pH and temperature, so the present method uses the much more unambiguous (1)H chemical shifts for assignment and (31)P intensities for quantification. By using 2D (1)H-(31)P total correlation spectroscopy (TOCSY) correlation experiments, we demonstrate that approximately 20 different lipids can be automatically and unambiguously assigned and quantified by this automatic method.
Robust and easy-to-use NMR sensor technology is proposed for accurate, on-site determination of fat and protein contents in milk. The two parameters are determined using fast consecutive 1H and 35Cl low-field NMR experiments on milk samples upon the 1:1 addition of a low-cost contrast solution. Reliable and accurate measurements are obtained without tedious calibrations and the need for extensive database information and may readily be conducted by non-experts in production site environments. This enables on-site application at farms or dairies, or use in laboratories harvesting significant reductions in costs and time per analysis as compared to wet-chemistry analysis. The performance is demonstrated for calibration samples, various supermarket milk products, and raw milk samples, of which some were analyzed directly in the milking room. To illustrate the wide application range, the supermarket milk products included both conventionally/organically produced, lactose-free milk, cow’s, sheep’s and goat’s milk, homogenized and unhomogenized milk, and a broad nutrient range (0.1–9% fat, 1–6% protein). Excellent agreement between NMR measurements and reference values, without corrections or changes in calibration for various products and during extensive periods of experiment conduction (4 months) demonstrates the robustness of the procedure and instrumentation. For the raw milk samples, correlations between NMR and IR, NMR and wet-chemistry, as well as IR and wet-chemistry results, show that NMR, in terms of accuracy, compares favorably with the other methods.
Solid‐state NMR may provide access to a wealth of information on molecular structure and dynamics. However, for many applications, the acquisition is challenged by broad resonances implying large spectral linewidths and low sensitivity. Conventionally, this is tackled by using costly and laboratory‐fixed spectrometers based on large high‐field superconducting magnets. In this Communication, we demonstrate that a range of challenging wide‐line solid‐state NMR spectra can be acquired on a robust, maintenance‐free, low‐cost benchtop/mobile NMR spectrometer with a sensitivity comparable to common high‐field instruments. The performance and versatility for recording sensitive wide‐line spectra is demonstrated through acquisition of 31P NMR of paramagnetic FePO4 and full quadupolar lineshapes of Al2O3 (27Al) and KNO3 (14N). Also, we introduce interleaved acquisition of frequency‐stepped slices providing a dramatic reduction of the required experiment time.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.