Highly sensitive, mechanically robust Al2O3 nanopores are fabricated and characterized. These sensors allow for size control with sub‐nanometer precision, chemical modification, and exhibit superior noise performance and increased lifetime over their solid‐state counterparts. This new class of nanopore sensor is used in dsDNA studies and finds broad application in bio‐nanotechnology.
RECEIVED DATE (to be automatically inserted after your manuscript is accepted if required according to the journal that you are submitting your paper to) *beer2@llnl.gov ABSTRACT. The first lab-on-chip system for picoliter droplet generation and RNA isolation, followed by reverse transcription, and PCR amplification with real-time fluorescence detection in the trapped droplets has been developed. The system utilized a shearing T-junction in a fused silica device to generate a stream of monodisperse picoliter-scale droplets that were isolated from the microfluidic channel walls and each other by the oil phase carrier. An off-chip valving system stopped the droplets on-chip, allowing thermal cycling for reverse transcription and subsequent PCR amplification without droplet motion. This combination of the established realtime reverse transcription-PCR assay with digital microfluidics is ideal for isolating single-copy RNA and virions from a complex environment, and will be useful in viral discovery and geneprofiling applications.
Roughly 33 million people worldwide are infected with HIV; disease burden is highest in resource-limited settings. One important diagnostic in HIV disease management is the absolute count of lymphocytes expressing the CD4(+) and CD8(+) receptors. The current diagnostic instruments and procedures require expensive equipment and trained technicians. In response, we have developed microfluidic biochips that count CD4(+) and CD8(+) lymphocytes in whole blood samples, without the need for off-chip sample preparation. The device is based on differential electrical counting and relies on five on-chip modules that, in sequence, chemically lyses erythrocytes, quenches lysis to preserve leukocytes, enumerates cells electrically, depletes the target cells (CD4 or CD8) with antibodies, and enumerates the remaining cells electrically. We demonstrate application of this chip using blood from healthy and HIV-infected subjects. Erythrocyte lysis and quenching durations were optimized to create pure leukocyte populations in less than 1 min. Target cell depletion was accomplished through shear stress-based immunocapture, using antibody-coated microposts to increase the contact surface area and enhance depletion efficiency. With the differential electrical counting method, device-based CD4(+) and CD8(+) T cell counts closely matched control counts obtained from flow cytometry, over a dynamic range of 40 to 1000 cells/μl. By providing accurate cell counts in less than 20 min, from samples obtained from one drop of whole blood, this approach has the potential to be realized as a handheld, battery-powered instrument that would deliver simple HIV diagnostics to patients anywhere in the world, regardless of geography or socioeconomic status.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.