Our results suggest that EEGNet is robust enough to learn a wide variety of interpretable features over a range of BCI tasks. Our models can be found at: https://github.com/vlawhern/arl-eegmodels.
Objective. Steady-State Visual Evoked Potentials (SSVEPs) are neural oscillations from the parietal and occipital regions of the brain that are evoked from flickering visual stimuli. SSVEPs are robust signals measurable in the electroencephalogram (EEG) and are commonly used in brain-computer interfaces (BCIs). However, methods for high-accuracy decoding of SSVEPs usually require hand-crafted approaches that leverage domain-specific knowledge of the stimulus signals, such as specific temporal frequencies in the visual stimuli and their relative spatial arrangement. When this knowledge is unavailable, such as when SSVEP signals are acquired asynchronously, such approaches tend to fail. Approach. In this paper, we show how a compact convolutional neural network (Compact-CNN), which only requires raw EEG signals for automatic feature extraction, can be used to decode signals from a 12-class SSVEP dataset without the need for user-specific calibration. Main results. The Compact-CNN demonstrates across subject mean accuracy of approximately 80 %, out-performing current state-of-the-art, handcrafted approaches using canonical correlation analysis (CCA) and Combined-CCA. Furthermore, the Compact-CNN approach can reveal the underlying feature representation, revealing that the deep learner extracts additional phase-and amplitude-related features associated with the structure of the dataset. Significance. We discuss how our Compact-CNN shows promise for BCI applications that allow users to freely gaze/attend to any stimulus at any time (e.g., asynchronous BCI) as well as provides a method for analyzing SSVEP signals in a way that might augment our understanding about the basic processing in the visual cortex.Evoked potentials are robust signals in the electroencephalogram (EEG) induced by sensory stimuli, and they have been used to study normal and abnormal function of the sensory cortex [1]. The most well-studied of these are Steady-State Visual Evoked Potentials (SSVEPs), which are neural oscillations in the visual cortex that are evoked from stimuli that temporally flicker in a narrow frequency band [2,3]. SSVEPs likely arise from a reorganization of spontaneous intrinsic brain oscillations in response to a stimulus [4]. Paradigms leveraging SSVEP responses have been used to investigate the organization of the visual system [5,6], identify biomarkers of disease and sensory function [7][8][9], and probe visual perception [10,11].The robustness of SSVEP has enabled its use as a control signal for brain computer interfaces (BCIs) that enable low-bandwith communication for individuals with catastrophic loss of motor functions, bypassing neuro-muscular pathways and establishing a communication link directly to the brain [12,13]. In a typical SSVEP BCI, a patient/subject is presented with a grid of squares on a computer monitor, where each square contains semantic information such as a letter, number, character, or action. Superimposed on these squares are visual flicker frequencies that uniquely "tag" each square, thus mapp...
Many of the most widely accepted methods for reliable detection of steady-state visual evoked potentials (SSVEPs) in the electroencephalogram (EEG) utilize canonical correlation analysis (CCA). CCA uses pure sine and cosine reference templates with frequencies corresponding to the visual stimulation frequencies. These generic reference templates may not optimally reflect the natural SSVEP features obscured by the background EEG. This paper introduces a new approach that utilizes spatio-temporal feature extraction with multivariate linear regression (MLR) to learn discriminative SSVEP features for improving the detection accuracy. MLR is implemented on dimensionality-reduced EEG training data and a constructed label matrix to find optimally discriminative subspaces. Experimental results show that the proposed MLR method significantly outperforms CCA as well as several other competing methods for SSVEP detection, especially for time windows shorter than 1 second. This demonstrates that the MLR method is a promising new approach for achieving improved real-time performance of SSVEP-BCIs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.