We present here the detection of dopamine (DA) at nanopipet electrodes with radii of hundreds of nanometers ranging from 160 nm to 480 nm. Dibenzo-18-crown-6 (DB18C6) was employed as an ionophore to facilitate DA transfer, resulting in a half-wave transfer potential, E1/2, DA, of −0.322 (±0.020) V vs. E1/2, TBA. Well-defined steady-state sigmoidal cyclic voltammograms were observed for the transfer of DA. High resolution scanning electron microscopy was used to measure the size and taper angle of the nanopipet electrodes. The detection is linear with concentration of DA ranging from 0.25 mM to 2 mM; calculated diffusion coefficient at nanopipet electrodes with above mentioned sizes is 4.87 (±0.28) × 10−10 m2/s. The effect of the common interferent ascorbic acid on DA detection with nanopipet electrodes was evaluated, where DA detection still shows linear behavior with well-defined sigmoidal CVs with E1/2, DA being −0.328 (±0.029) V vs. E1/2, TBA. The diffusion coefficient for DA transfer in MgCl2 with the presence of 2 mM AA was measured to be 1.93 (±0.59) × 10−10 m2/s on nanoelectrodes with radii from 161 nm to 263 nm, but the physiological concentration of 0.1 mM AA had no effect on DA’s diffusion coefficient.
Interface between two immiscible electrolyte solutions (ITIES) supported on the orifice of a pipet have become a powerful platform to detect a broad range of analytes. We present here the detection of γ-aminobutyric acid (GABA) with the nanoITIES pipet electrodes for the first time. GABA has a net charge of zero in an aqueous solution at pH ≈ 7, and it has not previously been detected at ITIES. In this work, we demonstrated GABA detection at ITIES in an aqueous solution at pH ≈ 7, where we introduced a novel detection strategy based on “pH modulation from the oil phase”. To the best of our knowledge, this is the first report of such. Current increases linearly with increasing concentrations of GABA, ranging from 0.25 mM to 1.0 mM. The measured half-wave transfer potential of GABA is −0.401 ± 0.010 V (n = 22) vs E1/2,TBA. The measured diffusion coefficient for GABA detection at nanoITIES pipet electrode is 6.09 (±0.58) × 10−10 m2/s (n = 5). Experimental results indicate that protons generated from octanoic acid dissociation in the oil phase do not come out from the oil phase into the aqueous phase; neither were protons produced in the aqueous phase. NanoITIES pipet electrodes with radii of 320–340 nm were used in the current study. This new strategy and knowledge presented here lays the groundwork for the future development of ITIES pipet electrodes, especially for the detection of electrochemically nonredox active analytes.
We present here amperometric electrodes for the selective and quantitative detection of acetylcholine. Detection was achieved based on electrodeposition of a carbon electrode with poly(3,4-ethylenedioxythiophene) (PEDOT) followed by drop-casting of...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.