Ultrasound echo intensity (EI) values are a popular assessment of muscle quality. The relationship between EI and total (%fat) and regional (%fat) body composition was examined in 40 men, prior to and after accounting for subcutaneous fat thickness. Uncorrected EI values suggest that muscle quality improves (r = -0.329 to -0.224; P = 0.038-0.165) with greater %fat and %fat. However, corrected EI values indicated that muscle quality decreases (r = 0.711 to 0.798; P < 0.001) with greater %fat and %fat.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.