This study aimed to compare contrast-enhanced CT (CE-CT) and 18 F-FDG PET/CT for response monitoring in metastatic breast cancer using the standardized response evaluation criteria RECIST 1.1 and PERCIST. The objective was to examine whether progressive disease was detected systematically earlier by one of the modalities. Methods: Women with biopsy-verified metastatic breast cancer were enrolled prospectively and monitored using combined CE-CT and 18 F-FDG PET/CT every 9-12 wk to evaluate response to first-line treatment. CE-CT scans and RECIST 1.1 were used for clinical decision-making without accessing the 18 F-FDG PET/CT scans. At study completion, 18 F-FDG PET/CT scans were unmasked and assessed according to PERCIST. Visual assessment was used if response criteria could not be applied. The modality-specific time to progression was defined as the time from the baseline scan until the first scan demonstrating progression. Paired comparative analyses for CE-CT versus 18 F-FDG PET/CT were applied, and the primary endpoint was earlier detection of progression by one modality. Secondary endpoints were time to detection of progression, response categorization, visualization of changes in response over time, and measurable disease according to RECIST and PERCIST. Results: In total, 87 women were evaluable, with a median of 6 (1-11) follow-up scans. Progression was detected first by 18 F-FDG PET/CT in 43 (49.4%) of 87 patients and first by CE-CT in 1 (1.15%) of 87 patients (P , 0.0001). Excluding patients without progression (n 5 32), progression was seen first on 18 F-FDG PET/CT in 78.2% (43/55) of patients. The median time from detection of progression by 18 F-FDG PET/CT to that of CE-CT was 6 mo (95% CI, 4.3-6.4 mo). At baseline, 76 (87.4%) of 87 patients had measurable disease according to PERCIST and 51 (58.6%) of 87 patients had measurable disease according to RECIST 1.1. Moreover, 18 F-FDG PET/CT provided improved visualization of changes in response over time, as seen in the graphical abstract. Conclusion: Disease progression was detected earlier by 18 F-FDG PET/CT than by CE-CT in most patients, with a potentially clinically relevant median 6-mo delay for CE-CT. More patients had measurable disease according to PERCIST than according to RECIST 1.1. The magnitude of the final benefit for patients is a perspective for future research.
The preferred nuclear medicine method for identification of hyperfunctioning parathyroid glands in hyperparathyroidism (HPT) develops continuously in relation to the technological progress. Diagnostic methods based on PET/CT have during recent years evolved with new tracer possibilities competing with traditional scintigraphic methods. This investigation is a head-to-head comparison of Tc-99m-sestamibi SPECT/CT gamma camera scintigraphy (Sestamibi SPECT/CT) and C-11-L-Methionin PET/CT imaging (Methionine PET/CT) for preoperative identification of hyperfunctioning parathyroid glands.Procedures: The study is a prospective cohort study including 27 patients diagnosed with primary hyperparathyroidism (PHPT). Two nuclear medicine physicians assessed all examinations independently and blinded. All scanning assessments were matched to the final surgical diagnosis as confirmed by histopathology. Biochemical monitoring of the therapeutical effects was performed preoperatively by PTHmeasurements and followed postoperatively for up to 12 months. Comparisons were made for differences in sensitivity and positive predictive value (PPV).Results: Twenty-seven patients (18 females, 9 males; mean age (range): 58.9 years (34.1-79)) were enrolled into the study. The 27 patients had a total of 33 identified sites of lesions of which 28 (85%) turned out to be histopathological verified hyperfunctioning parathyroid glands. The sensitivity and PPV for Sestamibi SPECT/CT were 0.71 and 0.95; that of Methionine PET/CT was 0.82 and 1, respectively. Both sensitivity and PPV were slightly lower for Sestamibi SPECT/CT than for Methionine PET/CT (-0.11, 95% confidence interval (95% CI): -0.29 to 0.08; -0.05, 95% CI: -0.14 to 0.04, respectively), but not to a statistically significant extent (p=0.38 and p=0.31). The sensitivity and PPV for diagnostic CT were 0.64 (95% CI: 0.44 to 0.81) and 1 (95% CI: 0.81 to 1).Conclusions: Methionine PET/CT performed comparable to Sestamibi SPECT/CT with respect to identification and localization of hyperfunctioning parathyroid glands prior to surgery.
No abstract
Results: From January 2000 to December 2019, 2752 mBC pts were enrolled of whom 1433 were included in the present analysis: 597 in the SFU group and 836 in the IFU group. Patients in the IFU group had a shorter median disease-free interval (60.6 and 52.9 months for SFU and IFU respectively, p¼0.01). No differences in OS were observed with a median OS of ) months for SFU and IFU groups respectively (HR 1.04, 95%CI 0.89-1.21, p¼0.64). In the subgroup analysis, no differences in OS were observed according to nodal involvement of primary tumor and among HER2-positive and luminal-like breast cancer patients. A worse outcome was demonstrated for triple-negative breast cancer patients diagnosed through IFU (HR 1.98,). Among the 157 HER2positive mBC pts diagnosed after 2015, no differences in OS were demonstrated for patients diagnosed through SFU or IFU (HR 0.86 95%CI 0.44-1.67).Conclusions: IFU seem to anticipate diagnosis of metastatic disease without increasing survival. Further randomized trials are needed to evaluate the role of different IFU strategies considering the current advances in imaging and anticancer treatments available nowadays.Clinical trial identification: NCT02284581.
We compared the image quality and quantification parameters through bayesian penalized likelihood reconstruction algorithm (Q.Clear) and ordered subset expectation maximization (OSEM) algorithm for 2-[18F]FDG-PET/CT scans performed for response monitoring in patients with metastatic breast cancer in prospective setting. We included 37 metastatic breast cancer patients diagnosed and monitored with 2-[18F]FDG-PET/CT at Odense University Hospital (Denmark). A total of 100 scans were analyzed blinded toward Q.Clear and OSEM reconstruction algorithms regarding image quality parameters (noise, sharpness, contrast, diagnostic confidence, artefacts, and blotchy appearance) using a five-point scale. The hottest lesion was selected in scans with measurable disease, considering the same volume of interest in both reconstruction methods. SULpeak (g/mL) and SUVmax (g/mL) were compared for the same hottest lesion. There was no significant difference regarding noise, diagnostic confidence, and artefacts within reconstruction methods; Q.Clear had significantly better sharpness (p < 0.001) and contrast (p = 0.001) than the OSEM reconstruction, while the OSEM reconstruction had significantly less blotchy appearance compared with Q.Clear reconstruction (p < 0.001). Quantitative analysis on 75/100 scans indicated that Q.Clear reconstruction had significantly higher SULpeak (5.33 ± 2.8 vs. 4.85 ± 2.5, p < 0.001) and SUVmax (8.27 ± 4.8 vs. 6.90 ± 3.8, p < 0.001) compared with OSEM reconstruction. In conclusion, Q.Clear reconstruction revealed better sharpness, better contrast, higher SUVmax, and higher SULpeak, while OSEM reconstruction had less blotchy appearance.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.