Background and purpose In preclinical radiation studies, there is great interest in quantifying the radiation response of healthy tissues. Manual contouring has significant impact on the treatment-planning because of variation introduced by human interpretation. This results in inconsistencies when assessing normal tissue volumes. Evaluation of these discrepancies can provide a better understanding on the limitations of the current preclinical radiation workflow. In the present work, interobserver variability (IOV) in manual contouring of rodent normal tissues on cone-beam Computed Tomography, in head and thorax regions was evaluated. Materials and methods Two animal technicians performed manually (assisted) contouring of normal tissues located within the thorax and head regions of rodents, 20 cases per body site. Mean surface distance (MSD), displacement of center of mass (ΔCoM), DICE similarity coefficient (DSC) and the 95th percentile Hausdorff distance (HD 95 ) were calculated between the contours of the two observers to evaluate the IOV. Results For the thorax organs, right lung had the lowest IOV (ΔCoM: 0.08 ± 0.04 mm, DSC: 0.96 ± 0.01, MSD:0.07 ± 0.01 mm, HD 95 :0.20 ± 0.03 mm) while spinal cord, the highest IOV (ΔCoM:0.5 ± 0.3 mm, DSC:0.81 ± 0.05, MSD:0.14 ± 0.03 mm, HD 95 :0.8 ± 0.2 mm). Regarding head organs, right eye demonstrated the lowest IOV (ΔCoM:0.12 ± 0.08 mm, DSC: 0.93 ± 0.02, MSD: 0.15 ± 0.04 mm, HD 95 : 0.29 ± 0.07 mm) while complete brain, the highest IOV (ΔCoM: 0.2 ± 0.1 mm, DSC: 0.94 ± 0.02, MSD: 0.3 ± 0.1 mm, HD 95 : 0.5 ± 0.1 mm). Conclusions Our findings reveal small IOV, within the sub-mm range, for thorax and head normal tissues in rodents. The set of contours can serve as a basis for developing an automated delineation method for e.g., treatment planning.
This Roadmap paper covers the field of precision preclinical radiation studies in animal models. It is mostly focused on models for cancer and normal tissue response to radiation, but also discusses other disease models. The recent technological evolutions in imaging, irradiation, dosimetry and monitoring that have empowered these kinds of studies is discussed, and many developments in the near future are outlined. Finally, clinical translation and inverse translation are discussed.
Objective: Delineation of relevant normal tissues is a bottleneck in image-guided precision radiotherapy workflows for small animals. A deep learning (DL) model for automatic contouring using standardized 3D micro cone-beam CT (μCBCT) volumes as input is proposed, to provide a fully automatic, generalizable method for normal tissue contouring in preclinical studies. Approach: A 3D U-net was trained to contour organs in the head (whole brain, left/right brain hemisphere, left/right eye) and thorax (complete lungs, left/right lung, heart, spinal cord, thorax bone) regions. As an important preprocessing step, Hounsfield units (HUs) were converted to mass density (MD) values, to remove the energy dependency of the μCBCT scanner and improve generalizability of the DL model. Model performance was evaluated quantitatively by Dice similarity coefficient (DSC), mean surface distance (MSD), 95th percentile Hausdorff distance (HD95p), and center of mass displacement (∆CoM). For qualitative assessment, DL-generated contours (for 40 and 80 kV images) were scored (0: unacceptable, manual re-contouring needed – 5: no adjustments needed). An uncertainty analysis using Monte Carlo dropout (MCD) uncertainty was performed for delineation of the heart. Main results: The proposed DL model and accompanying preprocessing method provide high quality contours, with in general median DSC > 0.85, MSD < 0.25 mm, HD95p < 1 mm and ∆CoM < 0.5 mm. The qualitative assessment showed very few contours needed manual adaptations (40 kV: 20/155 contours, 80 kV: 3/155 contours). The uncertainty of the DL model is small (within 2%). Significance: A DL-based model dedicated to preclinical studies has been developed for multi-organ segmentation in two body sites. For the first time, a method independent of image acquisition parameters has been quantitatively evaluated, resulting in sub-millimeter performance, while qualitative assessment demonstrated the high quality of the DL-generated contours. The uncertainty analysis additionally showed that inherent model variability is low.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.