BackgroundFor over 60 years, the Karnofsky Performance Status (KPS) has proven itself a valuable tool with which to perform measurement of and comparison between the functional statuses of individual patients. In recent decades conditions for patients have changed, and so too has the KPS undergone several adjustments since its initial development.DiscussionThe most important works regarding the KPS tend to focus upon a variety of issues, including but not limited to reliability, validity and health-related quality of life. Also discussed is the question of what quantity the KPS may in fact be said to measure. The KPS is increasingly used as a prognostic factor in patient assessment. Thus, questions regarding if and how it affects survival are relevant.In this paper, we propose an algorithm which uses a minimum of two and a maximum of three questions to facilitate an adequate and efficient evaluation of the KPS.SummaryThis review honors the original intention of the discoverer and gives an overview of adaptations made in recent years. The proposed algorithm suggests specific updates with the goal of ensuring continued adequacy and expediency in the determination of the KPS.
Reliability Measurement error s u m m a r yObjective: To estimate the reliability and measurement error of performance-based tests of physical function recommended by the Osteoarthritis Research Society International (OARSI) in people with hip and/or knee osteoarthritis (OA). Design: Prospective repeated measures between independent raters within a session and within-rater over a week interval. Relative reliability was estimated for 51 people with hip and/or knee OA (mean age 64.5 years, standard deviation (SD) 6.21 years; 47% females; 36 (70%) primary knee OA) on the 30s Chair Stand Test (30sCST), 40m Fast-Paced Walk Test (40mFPWT), 11-Stair Climb Test (11-step SCT), Timed Up and Go (TUG), Six-Minute Walk Test (6MWT), 10m Fast-Paced Walk Test (10mFPWT) and 20s Stair Climb Test (20sSCT) using intra-class correlation coefficients (ICC). Absolute reliability was calculated using standard error of measurement (SEM) and minimal detectable change (MDC). Results: Measurement error was acceptable (SEM < 10%) for all tests. Between-rater reliability was: optimal (ICC > 0.9, lower 1-sided 95% CI > 0.7) for the 40mFPWT, 6MWT and 10mFPWT; sufficient (ICC >0.8, lower 1-sided 95% CI > 0.7) for 30sCST, 20sSCT; unacceptable (lower 1-side 95% CI < 0.7) for 11-step SCT and TUG. Within-rater reliability was optimal for 40mFPWT, and 6MWT; sufficient for 30sCST and 10mFPWT and unacceptable for 11-step SCT, TUG and 20sSCT. Conclusions: The 30sCST, 40mFPWT, 6MWT and 10mFPWT, demonstrated, at minimum, acceptable levels of both between and within-rater reliability and measurement error. All tests demonstrated sufficiently small measurement error indicating they are adequate for measuring change over time in individuals with knee/hip OA.
This systematic review investigates ear cooling and cryotherapy in the prevention and treatment of inner ear damage and disease, within the context of animal models and clinical studies. A literature search was carried out in the databases Pubmed and Cochrane Library. Ten studies were identified concerning the otoprotective properties of cryotherapy. Nine of these were rodent in vivo studies (mice, rats, gerbils, guinea pigs). One study involved human subjects and investigated cryotherapy in idiopathic sensorineural hearing loss. The studies were heterogeneous in their goals, methods, and the models used. Disorder models included ischemia and noise damage, ototoxicity (cisplatin and aminoglycoside), and CI-electrode insertion. All ten studies demonstrated significant cryotherapeutic otoprotection for their respective endpoints. No study revealed or expressly investigated otodestructive effects. While limited in number, all of the studies within the scope of the review demonstrated some degree of cryotherapeutic, otoprotective effect. These promising results support the conducting of further work to explore and refine the clinical applicability and impact of cryotherpeutics in otolaryngology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.