Applying a physical training program to a group of obese women after 3 months of bariatric surgery could promote a significant increase in CRF only in the trained group, yet also showing that bariatric surgery alone caused an improvement in the lung function of both groups.
BackgroundCopper associated hepatitis (CAH) has been increasingly recognized in dogs, and speculation exists that hereditary defects in copper metabolism have been exacerbated by increased environmental copper exposure. However, no broad epidemiological investigations have been performed to investigate quantitative hepatic copper concentrations ([Cu]H) over time in both dogs that are (predisposed breed [PB]), and are not (non‐predisposed breed [NPB]), considered at‐risk for CAH.ObjectivesTo investigate [Cu]H in dogs and explore temporal, demographic, and histologic associations spanning 34 years.Animals546 archived liver specimens.MethodsRetrospective study. Searches of the Michigan State University Veterinary Diagnostic Laboratory database identified dogs that had undergone hepatic histopathologic assessment. Cases with archived tissue were reviewed and classified by breed, time period, and presence or absence of hepatitis. Inductively coupled plasma mass spectrometry was used to determine [Cu]H.ResultsIn time period 2009–2015, median [Cu]H were 101 μg/g and 313 μg/g greater than median [Cu]H in time period 1982–1988 for NPB and PB dogs, respectively (P < .001 for both comparisons). The proportion of dogs with [CU]H > 300 μg/g increased in NPB (28% to 49%) and PB dogs (48% to 71%) during these periods (P = .002 for both comparisons). Median [Cu]H in dogs with hepatitis increased 3‐fold over time in both NPB (P = .004) and PB populations (P < .001).Conclusions and Clinical ImportanceThe frequent recognition of CAH in recent years is likely due to the observed increases in [Cu]H over time. Importantly, effects are not limited to PB dogs.
Purpose: to identify the accuracy of the single-breath counting test to determine slow vital capacity in hospitalized patients and to evaluate the repeatability of the same examiner. Methods: a diagnostic study and the choice of techniques were randomly assigned. The area under the curve (receiver operating characteristic) was calculated from the slow vital capacity (20ml/kg) to evaluate the best psychometric characteristics of single-breath counting Test for this cutoff point. Repeatability observed by the same examiner was assessed using the Intraclass Correlation Coefficient. Results: 516 patients hospitalized for various diseases were analyzed. In the curve analysis (receiver operating characteristic/slow vital capacity=20ml/Kg), the value of 21 in single-breath counting test with a sensitivity of 94.44% and specificity of 76.62% (area under the curve =0.93, p<0.005) was found. The intraclass correlation coefficient value for the single-breath counting test was 0.976 with p>0.005. Conclusion: the single-breath counting test was a valid and repetitive technique, and may be an important screening option for assessment of lung function in the absence of specific equipment. This technique opens perspectives to replace slow vital capacity measurement in hospitals, which lack spirometric equipment, or in patients who may have a contagious disease, which has a risk of contamination and spread of disease from one patient to another.
Cardiopulmonary assessment through oxygen uptake efficiency slope (OUES) data has shown encouraging results, revealing that we can obtain important clinical information about functional status. Until now, the use of OUES has not been established as a measure of cardiorespiratory capacity in an obese adult population, only in cardiac and pulmonary diseases or pediatric patients. The aim of this study was to characterize submaximal and maximal levels of OUES in a sample of morbidly obese women and analyze its relationship with traditional measures of cardiorespiratory fitness, anthropometry and pulmonary function. Thirty-three morbidly obese women (age 39.1 ± 9.2 years) performed Cardiopulmonary Exercise Testing (CPX) on a treadmill using the ramp protocol. In addition, anthropometric measurements and pulmonary function were also evaluated. Maximal and submaximal OUES were measured, being calculated from data obtained in the first 50% (OUES50%) and 75% (OUES75%) of total CPX duration. In one-way ANOVA analysis, OUES did not significantly differ between the three different exercise intensities, as observed through a Bland-Altman concordance of 58.9 mL/min/log(L/min) between OUES75% and OUES100%, and 0.49 mL/kg/min/log(l/min) between OUES/kg75% and OUES/kg100%. A strong positive correlation between the maximal (r = 0.79) and submaximal (r = 0.81) OUES/kg with oxygen consumption at peak exercise (VO2peak) and ventilatory anaerobic threshold (VO2VAT) was observed, and a moderate negative correlation with hip circumference (r = -0.46) and body adiposity index (r = -0.50) was also verified. There was no significant difference between maximal and submaximal OUES, showing strong correlations with each other and oxygen consumption (peak and VAT). These results indicate that OUES can be a useful parameter which could be used as a cardiopulmonary fitness index in subjects with severe limitations to perform CPX, as for morbidly obese women.
The ISWT test generated superior metabolic and ventilatory stress than the 6MWT and may be more suitable for assessing cardiopulmonary fitness than self-paced tests.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.