This paper describes a tactile display for reproducing stiffness distributions based on magnetorheological (MR) fluid. This display can represent stiffness distribution by controlling the applied magnetic field locally. Computed tomography (CT) and endoscopy are currently used to diagnosis intravital conditions. However, CT cannot detect tumors smaller than 5 mm, and endoscopy can only diagnosis the tissue surface. Since tumors are stiffer than normal tissue, endoscopic palpation may be effective for detecting tumors smaller than 5 mm located beneath the tissue surface. To perform such palpation, a tactile display that can reproduce the spatial stiffness distribution of tissue is strongly required. For intravital tissue, the display must be capable of creating stiffness values ranging from about 200 to about 600 kPa with a spatial resolution of less than 5 mm. In the present study, a tactile display is proposed that exploits the ability of a MR fluid to change its stiffness in a magnetic field. In the proposed device, the MR fluid is encapsulated in an acrylic chamber covered by a thin flexible membrane. We first characterized the mechanical properties of the device and then, conducted sensory experiments with five subjects to verify that the device could display stiffness distribution. The magnetic field was produced by a cylindrical permanent magnet with a diameter of 5 mm, and the applied field strength was controlled by varying the separation between the magnet and the display. The experimental results indicated that the proposed display could successfully recreate the stiffness distribution including stiffness of tumor tissue under a local magnetic field of 200 mT. The device was then evaluated using five subjects, who were asked to touch the device with their index fingers and estimate the size of the stiff spot. Although the results varied among subjects, all were capable of perceiving spots smaller than 5 mm.
This paper demonstrates a tactile display to reproduce stiffness distribution using a Magneto-rheological (MR) fluid. Computed tomography (CT) scan and endoscope are widely used to diagnosis intravital condition and contribute the quality of life. However, CT scan cannot detect tumors smaller than 5 mm and endoscope can only diagnosis only surface of the tissue surface. Since tumors is stiffer than normal tissue, intravital palpation may be effective to detect tumors smaller than 5 mm. To perform intravital palpation, tactile displays to reproduce stiffness information from micro tactile sensors is needed. In present study, we propose tactile display using MR fluid to change its stiffness in an external magnetic field. MR fluid was encapsulated in an acrylic chamber covered by a thin PDMS membrane. Compression tests were conducted to evaluate mechanical properties of the display. Two types of probes were used. A narrow probe was used to perform detailed measurement and a wider probe was used to simulate how subjects felt. The experimental results indicated that the display could successfully create the stiffness of tumor under an external magnetic field of 200 mT. Then, the display was evaluated using five subjects. The results indicated all of the subjects perceived stiffer spot smaller than 5 mm under an external magnetic field of 100 mT
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.