Application of BIVAC to BV publications identified deficiencies in required study detail and delivery, especially for statistical analysis. Those deficiencies impact the veracity of BV estimates. BV data from BIVAC-compliant studies can be combined to deliver robust global estimates for safe clinical application.
Data on biological variation are used for many purposes in laboratory medicine but concern exists over the validity of the data reported in some studies. A critical appraisal checklist has been produced by a working group established by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) to enable standardised assessment of existing and future publications of biological variation data. The checklist identifies key elements to be reported in studies to enable safe accurate and effective transport of biological variation data sets across healthcare systems. The checklist is mapped to the domains of a minimum data set required to enable this process.
The online, selective isolation of protein-ligand complexes using cobalt(II)-coated paramagnetic affinity beads (PABs) and subsequent liquid chromatography-mass spectrometry (LC-MS) determination of specifically bound ligands is described. After in-solution incubation of an analyte mixture with His-tagged target proteins, protein-analyte complexes are mixed with the Co(II)-PABs and subsequently injected into an in-house built magnetic trapping device. Bioactive ligands bound to the protein-Co(II)-PABs are retained in the magnetic field of the trapping device while inactive compounds are removed by washing with a pH 7.4 buffer. Active ligands are online eluted toward the LC-MS system using a pH shift. In the final step of the procedure, the protein-Co(II)-PABs are flushed to waste by temporarily lowering the magnetic field. The proof-of-principle is demonstrated by using commercially available Co(II)-PABs in combination with the His-tagged human estrogen-receptor ligand-binding domain. The system is characterized with a number of estrogenic ligands and nonbinding pharmaceutical compounds. The affinities of the test compounds varied from the high micromolar to the subnanomolar range. Typical detection limits are in the range from 20 to 80 nmol/L. The system is able to identify binders in mixtures of compounds, with an analysis time of 9.5 min per mixture. The standard deviation over 24 h is 9%.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.