Purpose The aim of the study is to evaluate the impact of myocardial 123I-metaiodobenzylguanidine (MIBG) in the diagnosis, clinical management, and differential diagnosis of Parkinson disease (PD) and non-PD parkinsonism. Methods The study enrolled 41 patients with parkinsonism. An initial diagnosis was reached after thorough clinical and imaging evaluation. After 2 to 5 years of follow-up, a final diagnosis was established. All patients underwent, soon after their initial visit, presynaptic striatal DaT scintigraphy with 123I-FP-CIT (DaTscan) and 123I-MIBG myocardial scintigraphy. DaTscan is not specific to distinguish among different types of neurodegenerative parkinsonism. 123I-MIBG myocardial scintigraphy displays the functional status of cardiac sympathetic nerves, which is reduced in PD/dementia with Lewy bodies (DLB) and normal in atypical parkinsonian syndromes and secondary or nondegenerative parkinsonism. Results No patients showed adverse effects during or after both scintigraphies. A positive DaTscan was found in all patients in the PD/DLB group (17/17) and in 15 of 24 patients in the non-PD group. Myocardial 123I-MIBG scintigraphy was associated with lower sensitivity (82% vs 100%) but higher specificity than DaTscan (79% vs 38%) in diagnosis PD/DLB from non-PD parkinsonism. A positive scan result on both techniques, to confirm diagnosis of PD/DLB, significantly improved the specificity of DaTscan, from 38% to 75%, with no reduction in sensitivity. Conclusions Myocardial 123I-MIBG imaging provides complementary value to 123I-FP-CIT in the proper diagnosis, treatment plan, and differential diagnosis between PD and other forms of parkinsonism.
Objectives We investigated the clinical impact of single-photon emission computed tomography/computed tomography (SPECT/CT) bone scintigraphy combined with 16-slice CT on metastatic workup and treatment planning in a large cancer patient series. Methods Between January 2019 and January 2020, a total of 600 cancer patients were prospectively evaluated with whole-body planar bone scan (wbPBS) for staging or restaging purposes. 272/600 had equivocal lesions on wbPBS and 265/272 underwent additionally a targeted SPECT/CT bone scintigraphy on designated regions. Findings were classified as benign (score 1), metastatic (score 2) and inconclusive (score 3). Findings from SPECT/CT bone scintigraphy were compared with the results of wbPBS. Results A total of 668 lesions were considered as unclear οn wbPBS and were re-evaluated through targeted SPECT/CT bone scintigraphy. Definite diagnostic findings on SPECT/CT bone scintigraphy were obtained in 227/265 (85.7%) patients and in 592/668 (88.6%) lesions vs. 15.4% of wbPBS alone. On per-patient analyses, 38.9% of patients were considered definitely nonmetastatic and 46.8% as definitely metastatic. On per lesion analyses using SPECT/CT bone scintigraphy, corresponding diagnostic rates were 47.5 and 41.2%. Although the addition of SPECT/CT bone scintigraphy significantly reduced the rate of equivocal wbPBS results (83.1%), it failed to provide a conclusive diagnosis in a relatively small proportion of lesions 76/668 (11.4%) in 38 patients. Conclusions SPECT/CT bone scintigraphy afforded a significant reduction of the number of patients with equivocal findings who needed further evaluation with other imaging modalities, preventing unnecessary delays in diagnosis and potential changes in disease staging and treatment planning. Moreover, SPECT/CT bone scintigraphy slightly increased diagnostic sensitivity.
Cardiac neuroendocrine tumors (NETs) are particularly rare tumors that can lead to a very poor clinical outcome, partly because of metastases but mainly because of manifestations of the hormonal activity they exhibit. Prompt diagnosis is important in order to start the most effective treatment for their removal or management, with the fewest complications. They are often difficult to diagnose, especially in their early stages. One of the reasons for this is that the heart is an organ with a high rate of metabolism and is located in close proximity to other highmetabolism organs. In addition, the anatomic location and their small size render their diagnosis extremely challenging. In recent years, hybrid imaging methods have revolutionized the diagnostic approach to oncology patients and have established a place in the diagnosis of cardiac NETs, because they provide both anatomical and functional information at the same time. Positron emission tomography/computed tomography (PET/CT), PET/magnetic resonance imaging (PET/MRI) and single-photon emission computed tomography/CT (SPECT/CT) are widely used in clinical practice because of the very important metabolic information, the high sensitivity and specificity. However, prospective studies are needed to confirm the true clinical and prognostic value of various hybrid imaging diagnostic techniques in cardiac NETs.
We studied the diagnostic value of 16 slices of single photon emission computed tomography (SPECT)/computed tomography (CT) in the anatomical localization, image interpretation and extra-sentinel lymph nodes (SLNs) detection compared to dynamic and static planar radioisotopic lymphoscintigraphy (PLS) in patients with melanoma. Eighty-two patients with melanoma underwent dynamic PLS, static PLS and SPECT/CT. Data were obtained using a dual head SPECT/CT 16 slices γ-camera. We evaluated the number and localization of SLNs detected with each imaging method. SPECT/CT demonstrated 48 additional SLNs in comparison with PLS in 29 patients. In five truncal and seven head-neck lesions, dynamic and static PLS failed to detect the SLNs found on SPECT/CT (false negative). In one case of truncal and one case of lower limb melanoma, the foci of increased activity interpreted on PLS as possible SLNs were confirmed to be non-nodal sites of uptake on SPECT/CT (false positive). PLS underestimated the number of SLNs detected, whereas SPECT/CT revealed higher agreement compared to the respective number from histological reports. SPECT/CT showed a better prediction of the number of SLNs and higher diagnostic parameters in comparison to planar imaging. SPECT/CT is an important complementary diagnostic modality to PLS, that improves detection, preoperative evaluation, anatomical landmarks of SLNs and surgical management of patients with melanoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.