Renal artery aneurysm (RAA) concomitant with a renal arteriovenous fistula (RAVF) has been infrequently reported in the literature. We report a case of a 42-year-old man suffering from a giant RAA combined with a congenital high-flow RAVF. The contrast-enhanced CTA showed a 12.7-cm RAA synchronous with an RAVF between the right renal artery and a draining vein. After a comprehensive preoperative assessment, an endovascular approach was decided. Successful embolization was performed using an Amplatzer vascular Plug, and multiple coils. Completion angiogram demonstrated no flow into the RAA. The results of longterm follow-up demonstrate that endovascular techniques are safe and effective for the management of RAAs combined with high-flow RAVF.
Background Aortic neck wall rupture during endovascular repair of abdominal aortic aneurysms (EVAR) is an underreported potentially fatal complication. Only a few cases have been reported. The main cause of this complication is repeated attempts at balloon inflation or overdilation to treat an intraoperative Type 1a endoleak. We report three cases complicated by procedure-related aortic neck wall rupture during EVAR. We also review the literature regarding the causes and outcomes of this complication. Methods Medical records of all patients undergoing EVAR between January 2009 and March 2019 were retrospectively reviewed. Results Overall, 824 EVAR procedures were performed, and rupture of the aortic neck wall was observed in three patients. In all cases, a Type 1a endoleak was observed and, in all cases, repeated ballooning attempts had been performed to resolve the endoleaks. In all cases, conversion to open repair was performed and all patients survived. Conclusion In cases of Type 1a endoleak, a maximum of two ballooning attempts should be performed even if a Type 1a endoleak persists. In case of intraoperative aortic neck wall rupture, control of the hemorrhage should be achieved immediately by advancing the balloon above the site of rupture. Emergency surgical conversion in case of hemodynamic stability is the first choice. According to the literature, emergency surgical conversion, especially in cases of endograft with suprarenal fixation, is associated with significant morbidity and mortality rates, mainly due to hemorrhage and to the length of the procedure required to repair the aortic neck wall injury.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.