Background There is a lack of agreement among measures of asthma control in children. In Central Europe, body plethysmography is additionally used for asthma monitoring. However, its value is still unclear. Objectives We investigated the possible additional value of body plethysmographic measures (specific resistance, residual volume‐total lung capacity ratio [RV/TLC]) compared with spirometric measures forced expiratory volume in 1 second (FEV 1), forced vital capacity (FVC), FEV 1/FVC, forced expiratory flow at 25% to 75% of forced vital capacity (FEF 25‐75), and fraction of exhaled nitric oxide (FeNO) for assessment of asthma control. Methods One hundred and forty‐five asthmatic children aged 5 to 17 were included. All children performed measurements of FeNO, spirometry, and body plethymography. Asthma control was assessed by the asthma control test (c‐ACT/ACT) and a doctor's assessment of asthma control. Results Investigating single lung function parameters, FEV1, FEV 1/FVC, FEF 25‐75 and RV/TLC differed between controlled and partly controlled asthma. However, we found no differences between controlled and uncontrolled asthma with regard to single lung function parameters or for any parameter if investigated in a multivariable approach. This was also true if we combined obtained parameters from spirometry (comparing pathologic vs normal spirometry). Investigating the combination of body plethysmography and doctor's assessment of asthma control a significant association was found ( P = 0.02). Furthermore, combined spirometry and body plethysmography showed a significant association with both doctor's assessed asthma control ( P = 0.009) and the c‐ACT/ACT ( P = 0.04). The addition of FeNO did not improve the results. Conclusions The combination of body plethysmography and spirometry shows best agreement with asthma control in children compared with spirometry or body plethysmography alone. Further studies are needed to find out whether additional measurements of body plethysmography improve the outcome of children in asthma monitoring.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.