The cold galvanizing coatings (CGCs) are used to repair old hot-dip galvanized steel (HDG) in numerous anticorrosion engineering, but poor adhesion of the CGC restricts its large-scale applications in the industries. For the purpose of overcoming the weak adhesion problems of the CGC on HDG, γ-chloropropyl triethoxysilane (CPTES) was added directly into cold galvanizing coatings (CPTES/CGC). Interface characteristics and related corrosion protection behaviors were investigated by the pull-off adhesion test, water contact angle measurements, Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscope (SEM), and electrochemical tests. The experimental results revealed that, there is an increase by 19.1% of the CPTES/CGC surface free energy when compared with that of CGC. In addition, Si–O–Si and Si–O–Zn bonds were found in the CPTES/CGC, which indicate new network structures formed inside the CPTES/CGC, between the interface of the CPTES/CGC and HDG substrate, resulting in dry adhesion, wet adhesion, and the cathodic protection time of CPTES/CGC increased by 50% and 200% and 300% respectively compared with the CGC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.