Background Circumcaval ureter is a rare congenital anomaly resulting from the persistence of embryonic venous system. This anomaly is characterized by running of affected ureter around caudal vena cava (CVC). Case presentation In this report, circumcaval ureter was found in a 2‐year‐old female cat attending as normal sample group in another research. This cat passed all health checkup protocols before computed tomography (CT) was performed. Conclusion The contrast‐enhanced computed tomographic (cCT) images clearly revealed the dislocation of the right ureter that course around CVC and uterine body. This is the first report of feline circumcaval concurrent with circumuterine ureter detected by cCT.
Background It is difficult to examine mild to moderate feline intra-thoracic lymphadenopathy via and thoracic radiography. Despite previous information from computed tomographic (CT) images of intra-thoracic lymph nodes, some factors from animals and CT setting were less elucidated. Therefore, this study aimed to investigate the effect of internal factors from animals and external factors from the CT procedure on the feasibility to detect the intra-thoracic lymph nodes. Twenty-four, client-owned, clinically healthy cats were categorized into three groups according to age. They underwent pre- and post-contrast enhanced CT for whole thorax followed by inter-group evaluation and comparison of sternal, cranial mediastinal, and tracheobronchial lymph nodes. Results Post contrast-enhanced CT appearances revealed that intra-thoracic lymph nodes of kittens were invisible, whereas the sternal, cranial mediastinal, and tracheobronchial nodes of cats aged over 7 months old were detected (6/24, 9/24 and 7/24, respectively). Maximum width of these lymph nodes were 3.93 ± 0.74 mm, 4.02 ± 0.65 mm, and 3.51 ± 0.62 mm, respectively. By age, lymph node sizes of these cats were not significantly different. Transverse lymph node width of males was larger than that of females (P = 0.0425). Besides, the detection score of lymph nodes was affected by slice thickness (P < 0.01) and lymph node width (P = 0.0049). Furthermore, an irregular, soft tissue structure, possibly the thymus, was detected in all juvenile cats and three mature cats. Conclusions Despite additional information on intra-thoracic lymph nodes in CT images, which can be used to investigate lymphatic-related abnormalities, age, sex, and slice thickness of CT images must be also considered.
Background Thoracic radiography in awake cats is a common procedure for the evaluation of pulmonary metastasis in feline mammary gland carcinoma (MGC). However, due to poor sensitivity, computed tomography (CT) is progressively taking its place. To perform CT in animals, general anesthesia is normally preferred but can cause lung atelectasis, affecting lung interpretation. Besides, MGC is often found in senile cats that are concurrently affected with other diseases, increasing anesthetic risk. Therefore, this study was aimed at comparing the effect of anesthesia on lung atelectasis observed through CT in clinically healthy cats and comparing the feasibility of non-anesthetic CT with non-anesthetic radiography in the detection of lung lesions in feline MGC. Thoracic CTs from anesthetized, clinically healthy cats and non-anesthetized either clinically healthy cats or MGC-affected cats were reviewed. In clinically healthy cats, motion artifacts and characteristics of lung atelectasis were observed and compared. In MGC-affected cats, motion artifacts were observed and compared to clinically healthy cats, and the number of MGC-affected cats, the number and characteristics of lung lesions were compared between non-anesthetic thoracic CT and radiography. Results Anesthesia significantly increased lung CT attenuation (P = 0.0047) and was significantly correlated with lung atelectasis (OR = 15; CI 2.02–111.18; P = 0.0081), particularly of the cranial lung lobe. Nonetheless, significantly higher motion artifacts in the caudal thoracic area were found in non-anesthetized healthy cats (P = 0.0146), but comparable low motion artifacts were observed in anesthetized healthy and MGC-affected cats. Non-anesthetic CT revealed higher numbers of MGC-affected cats and pulmonary nodules with a significantly lower nodular diameter (P = 0.0041) than those observed on radiographs. The smallest nodular diameters detected on radiographs and CT were 2.5 and 1.0 mm, respectively. Furthermore, CT showed additional information such as intra-thoracic lymphadenopathy, that could not be seen on radiographs. Conclusions Despite the motion artifacts, CT without anesthesia is a sensitive technique as it provides better lung inflation. Furthermore, compared to non-anesthetic radiography, non-anesthetic CT provided more information such as higher number of pulmonary nodules of a smaller size, including more distinct intra-thoracic lesions, such as lymphadenopathy, in MGC-affected cats.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.