Identification of responsible sources of pollution using physical parameter particulate matter (PM)10 in a critically polluted area is discussed in this paper. Database was generated by Ambient Air Quality Monitoring (AAQM) with respect to PM10 and PM2.5 in 18 monitoring stations at Jharia coalfield as per the siting criteria (IS: 5182, Part XIV) during 2011 to 2012. Identification of the probable sources of PM10 was carried out through particle size, shape, morphology analysis (scanning electron microscopy (SEM)), suitable compounds (X-ray diffraction (XRD)) and elements (energy-dispersive spectroscopy (EDS)). Monitoring stations nearby opencast mine were affected by the big-sized and irregular-shaped particles; on the other hand, monitoring stations nearby city were affected by the small-sized and regular-shaped particles. In a city area, additional sources like diesel generator (DG) set, construction activities, coal burning, etc., were identified. Blistering effects were also observed in the particles from mine fire-affected areas. Using the X-ray diffraction technique, presence of FeS2, CuO, FeSO4 and CuSO4 compounds was observed, which indicates the effects of mine fire on particulate emission due to presence of SO4(2-) and S2- ions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.