Background: Recent studies on the PRESERFLO MicroShunt suggest that it may be effective in lowering intraocular pressure (IOP); however, the number of studies on this device remains limited. Therefore, we assessed the efficacy of the PRESERFLO MicroShunt in patients with glaucoma and performed a meta-analysis of published results. Methods: Prospective study including all patients that underwent PRESERFLO MicroShunt surgery from 2018 onwards. Sub-analyses were performed for cataract-combined procedures. To compare our results, we performed a systematic review and meta-analysis. IOP, IOP-lowering medication and surgical complications reported in the retrieved studies were assessed. Results: A total of 72 eyes underwent PRESERFLO-implant surgery (59 as standalone procedure and 13 as cataract-combined procedure). No significant differences were found in IOP and IOP-lowering medication between both groups. The mean ± standard deviation IOP and IOP-lowering medications of both groups taken together declined from 21.72 ± 8.35 to 15.92 ± 8.54 mmHg (p < 0.001, 26.7% reduction) and 3.40 to 0.93 (p < 0.001, 72.6% reduction) at 1 year follow-up, respectively. Secondary surgeries were required in 19.4% of eyes, the majority (71.4%) within 6 months. The meta-analysis including 14 studies (totaling 1213 PRESERFLO MicroShunt surgeries) from the systematic review showed a mean preoperative IOP and IOP-lowering medication of 22.28 ± 5.38 and 2.97 ± 1.07, respectively. The three-years postoperative pooled mean was (weighted mean difference, 95% CI) 11.07 (10.27 [8.23–12.32], p < 0.001) mmHg and 0.91 (1.77 [1.26–2.28], p < 0.001) for IOP and IOP-lowering medication, respectively. The most common reported complication was hypotony (2–39%). Conclusion: The PRESERFLO MicroShunt is effective and safe in lowering IOP and the number of IOP-lowering medications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.