Polyether-ether-ketone (PEEK) biomaterial has been increasingly employed for orthopedic, trauma, spinal, and dental implants due to its biocompatibility and in vivo stability. However, a lack of bioactivity and binding ability to natural bone tissue has significantly limited PEEK for many challenging dental implant applications. In this work, nanocomposites based on PEEK reinforced with bioactive silicate-based bioceramics (forsterite or bioglass) as nanofillers were prepared using high energy ball milling followed by melt blending and compression molding. The influence of nanofillers type and content (10, 20 and 30 wt.%) on the crystalline structure, morphology, surface roughness, hydrophilicity, microhardness, elastic compression modulus, and flexural strength of the nanocomposites was investigated. The scanning electron microscopy images of the nanocomposites with low nanofillers content showed a homogenous surface with uniform dispersion within the PEEK matrix with no agglomerates. All nanocomposites showed an increased surface roughness compared to pristine PEEK. It was found that the incorporation of 20 wt.% forsterite was the most effective in the nanocomposite formulation compared with bioglass-based nanocomposites; it has significantly improved the elastic modulus, flexural strength, and microhardness. In vitro bioactivity evaluation, which used biomimetic simulated body fluid indicated the ability of PEEK nanocomposites loaded with forsterite or bioglass nanofillers to precipitate calcium and phosphate bone minerals on its surface. These nanocomposites are expected to be used in long-term load-bearing implant applications and could be recommended as a promising alternative to titanium and zirconia when used as a dental implant material.
Objective The current study was designed to assess the bonding strength of EndoSeal MTA and AH Plus sealers after using three irrigation protocols as follows: (1) 17% Ethylenediamine tetraacetic acid, (2) 7% maleic acid, and (3) 37% phosphoric acid. Materials and Methods Push-out bond strength was evaluated for 60 middle root slices of 1-mm thickness each. They were horizontally cut from freshly extracted single-rooted human teeth. A hole in the root canal was made using a carbide round bur of 1.1 mm in diameter in a middle third root slice. Specimens were dipped in 2.5% NaOCl, and then they were grouped into three groups; G1: 17% EDTA, G2: 7% maleic acid, and G3: 37% phosphoric acid as a final irrigant for 3 minutes. Each group was subdivided into two subgroups, according to the type of sealer, either EndoSeal MTA or AH Plus. Statistical Analysis After the full set of the sealer, the bond strength was evaluated with the push-out test by applying a force to each slice using a plunger with a 1-mm diameter. The one-way Tukey's post hoc test, analysis of variance (ANOVA) test, and Student's t-test were utilized to gather data and statistically evaluate it. Results The irrigation protocol used exhibited significant influence on the bond strength of EndoSeal MTA and AH Plus sealers. AH Plus sealer subgroups showed the highest bond strength with 7% maleic acid, followed by 37% phosphoric acid, and 17% EDTA. While in the EndoSeal MTA sealer subgroups, the highest bond strength was shown with the 17% EDTA followed by 7% maleic acid and 37% phosphoric acid, respectively. Conclusion The present study revealed that the type of the final irrigant significantly impacts the bond strength of the sealer used. The AH Plus sealer bond strength was improved by using the 7% maleic acid as a final irrigant. In contrast, the EndoSeal MTA sealer showed the best results with the 17% EDTA as a final irrigant.
Pressable ceramic restorations have been introduced and investigated, and found comparable to CAD/CAM ceramic in terms of mechanical properties; however, the effect of toothbrushing on the pressable ceramic has not been thoroughly investigated. The objective of the current study was to assess the effect of artificial toothbrushing simulation on the surface roughness, microhardness, and color stability of different ceramic materials. Three lithium disilicate-based ceramics (IPS Emax CAD [EC], IPS Emax Press [EP]; (Ivoclar Vivadent AG), and LiSi Press [LP] (GC Corp, Tokyo, Japan)) were examined. For each ceramic material, eight bar-shaped specimens were prepared and subjected to 10,000 brushing cycles. Surface roughness, microhardness, and color stability (∆E) were measured before and after brushing. Scanning electron microscopy (SEM) was used for surface profile analysis. The results were analyzed using one-way ANOVA, Tukey’s post hoc test, and paired sample t-test α = 0.05. The findings revealed a non-significant decrease in the surface roughness of EC, EP, and LP groups (p > 0.05), and both LP and EP have the lowest surface roughness values (0.64 ± 0.13, 0.64 ± 0.08 µm) after brushing, respectively. Toothbrushing showed a decrease in the microhardness of the three groups: EC and LP, p < 0.001; EP, p = 0.012). EP showed the lowest hardness value after brushing (862.45 ± 273.83). No significant changes (∆E) were observed in all groups (p > 0.05); however, the EC group was found to be considerably affected by color changes, in comparison to the EC and LP groups. Toothbrushing had no effect on surface roughness and color stability of all tested materials, but it decreased the microhardness. Material type, surface treatments, and glazing of ceramic materials contributed to the surface changes in the ceramic materials, necessitating further investigations in terms of the toothbrushing effect with different glazing as variables.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.