Background: Hallux valgus is one of the most common surgically corrected forefoot deformities. Compared to open procedures, minimally invasive (MIS) treatment of hallux valgus has resulted in decreased operative time, reduced complication rates, and greater patient satisfaction. Historically, distal chevron osteotomies are the standard for moderate hallux valgus correction. To our knowledge, no studies have evaluated biomechanical strength of transverse and chevron distal first metatarsal osteotomy (DMO) constructs. The purpose of this study was to evaluate the biomechanical strength of these techniques. Methods: Eighteen cadaveric specimens (9 matched pairs) were randomized to transverse or chevron DMO. Each technique was performed by a separate fellowship-trained orthopedic foot and ankle surgeon. Radiographic images were analyzed. Biomechanical testing was performed using Instron Mechanical System. Ultimate load to failure, yield load, and stiffness were assessed. A 10-N preload was applied to the sesamoid bones for stability. A coaxial compression rate (10 mm/min) was applied until failure was observed. Mean and standard deviations were compared. All cadaveric specimens were male. Results: There was no significant difference in percent metadiaphyseal shift between osteotomies ( P = .453). The most common mode of failure was fracture at screw insertion site (55.6%), followed by failure at osteotomy site (44.4%). A trend toward increased ultimate load to failure ( P = .480), yield load ( P = .054), and stiffness ( P = .438) among transverse compared to chevron osteotomy was observed, but this difference was not statistically significant. Conclusion: Biomechanical testing demonstrated no significant difference in ultimate load, yield load, and stiffness between MIS transverse and chevron osteotomy constructs; a trend toward increased strength in the transverse osteotomy cohort was observed. Chevron osteotomies may result in early failure by relative ease of cutout through cancellous bone compared to transverse osteotomies in which failure requires cortical cutout. Clinical Relevance: Use of MIS techniques for hallux valgus correction is gaining clinical traction. Although various clinical studies have evaluated outcomes of these MIS techniques, biomechanical studies have been minimal. Specifically, the potential biomechanical benefits of various MIS hallux valgus osteotomy techniques have not been delineated to date. The content of this manuscript is quite timely, given the rise in use of these MIS techniques.
Background Medial column internal rotation in hallux valgus (HV) can be measured using weight-bearing computed tomography (WBCT). Anteroposterior weight-bearing foot radiographs’ (WBXR) ability to estimate medial column internal rotation in HV was evaluated comparing these measurements with those obtained from WBCT. Methods Three observers evaluated WBCT and WBXR of 33 HV feet twice. Medial column internal rotation was measured with WBCT and classified into 3 levels according to WBXR findings. Intra- and interobserver reliability were obtained for WBXR and WBCT, in addition to WBXR-WBCT correlation. Results WBXR and WBCT intraobserver agreement was substantial and near perfect, respectively (κ 0.79 and 0.84). Their interobserver agreement was excellent (intraclass correlation 0.85 and 0.9, respectively). The WBXR-WBCT correlation was substantial (κ 0.68). WBXR diagnostic accuracy to predict the WBCT results was 85%. Conclusions The proposed method for medial column internal rotation measurement using WBXR is reliable and has a substantial agreement with WBCT measurements. Levels of Evidence Level III
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.