Background Cancer and spinal surgery are both considered risk factors for venous thromboembolism (VTE). However, the risk of symptomatic VTE for patients undergoing surgery for spine metastases remains undefined. Questions/purposes The purposes of this study were to: (1) identify the proportion of patients who develop symptomatic VTE within 90-days of surgical treatment for spine metastases; (2) identify the factors associated with the development of symptomatic VTE among patients receiving surgery for spine metastases; (3) assess the association between the development of postoperative symptomatic VTE and 1-year survival among patients who underwent surgery for spine metastases; and (4) assess if chemoprophylaxis increases the risk of wound complications among patients who underwent surgery for spine metastases. Methods Between 2002 and 2014, 637 patients at two hospitals underwent spine surgery for metastases. We considered eligible for analysis adult patients whose procedures were to treat cervical, thoracic, or lumbar metastases (including lymphoma and multiple myeloma). At followup after 90 days and 1 year, respectively, 21 of 637 patients (3%) and 41 of 637 patients (6%) were lost to followup. In general, we used 40 mg of enoxaparin or 5000 IUs subcutaneous heparin every 12 hours. Patients on preoperative chemoprophylaxis continued their initial medication postoperatively. All chemoprophylaxis was started 48 hours after surgery and continued day to day but was discontinued if a bleeding complication developed. Low-molecular-weight heparin (including enoxaparin and dalteparin, in general dosages of respectively 40 mg and 5000 IUs daily) was the most commonly used chemoprophylaxis in 308 patients (48%). Subcutaneous heparin was injected into 127 patients (20%); aspirin was used for 92 patients (14%); and warfarin was administered in 21 Each author certifies that neither he, nor any member of his immediate family, have funding or commercial associations (consultancies, stock ownership, equity interest, patent/licensing arrangements, etc) that might pose a conflict of interest in connection with the submitted article. Clinical Orthopaedics and Related Research® neither advocates nor endorses the use of any treatment, drug, or device. Readers are encouraged to always seek additional information, including FDA approval status, of any drug or device before clinical use. Each author certifies that his institution approved the reporting of this investigation and that all investigations were conducted in conformity with ethical principles of research.
Context.— Related to the advances in prenatal diagnosis and the emergence of medically challenging situations, there has been an increased interest in conducting a pathologic study of first-trimester abortion products. Objective.— To evaluate measurements across a large group of first-trimester spontaneous abortion specimens. Potential goals include a validation of prenatal embryo and gestational-sac measurements as a function of gestational age (GA). Design.— A retrospective case study of first-trimester spontaneous abortions between June 2015 and April 2017 in Centro de Genética Clínica Embryo-Fetal Pathology Laboratory, Porto, Portugal. Considering the inclusion criteria, 585 complete gestational sacs, 182 embryos, and 116 umbilical cords were selected. We recorded the weight of the gestational sacs and embryos and measurements of gestational sacs, umbilical cords, and embryo crown-rump length. Models were computed using regression techniques. Results.— Gestational-sac diameter percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval the diameter increased an average of 3 mm. Umbilical cord length percentiles 5, 25, 50, 75 and 95 were calculated according to GA, and at each 1-week interval, the length increased an average of 1.35 mm. Embryo crown-rump length estimated mean ± SD values were GA 6 weeks, 5.3 ± 2.3 mm; GA 7 weeks, 9.4 ± 4.8 mm; GA 8 weeks, 13.7 ± 8.2 mm; GA 9 weeks, 20.8 ± 9.1 mm; GA 10 weeks, 22.6 ± 13.4 mm; GA 11 weeks, 29.4 ± 12.9 mm; and GA 12 weeks, 52 mm. Conclusions.— Pathologic measurements obtained should be compared to expected measurements and correlated with ultrasound findings, clinical information, and microscopic findings. Deviations from expected values could lead to an understanding of early pregnancy loss.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.