Herein we report an electrochemical DNA biosensor for the rapid detection of sequence (5' AAT GGA TTT ATC TGC TCT TCG 3') specific for the breast cancer 1 (BRCA1) gene. The proposed electrochemical genosensor is based on short oligonucleotide DNA probe immobilized onto zinc oxide nanowires (ZnONWs) chemically synthesized onto gold electrode via hydrothermal technique. The morphology studies of the ZnONWs, performed by field emission scanning electron microscopy (FESEM), showed that the ZnO nanowires are uniform, highly dense and oriented perpendicularly to the substrate. Recognition event between the DNA probe and the target was investigated by differential pulse voltammetry (DPV) in 0.1 M acetate buffer solution (ABS), pH 7.00; as a result of the hybridization, an oxidation signal was observed at +0.8 V. The influences of pH, target concentration, and non-complimentary DNA on biosensor performance were examined. The proposed DNA biosensor has the ability to detect the target sequence in the range of concentration between 10.0 and 100.0 µM with a detection limit of 3.32 µM. The experimental results demonstrated that the prepared ZnONWs/Au electrodes are suitable platform for the immobilization of DNA.
The selective detection of dopamine (DA) is of great importance in the modern medicine because dopamine is one of the main regulators in human behaviour. In this study, ZnO/CuO nanohybrid structures, grown on the gold coated glass substrate, have been investigated as a novel electrode material for the electrochemical detection of dopamine. Scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) techniques were used for the material characterization and the obtained results are in good agreement. The selective determination of dopamine was demonstrated by cyclic voltammetry (CV) and amperometric experiments. The amperometric response was linear for dopamine concentrations between 1.0 x 10(-3) and 8.0 mM with a sensitivity of 90.9 μA mM(-1) cm(-2). The proposed dopamine biosensor is very stable, selective over common interferents as glucose, uric acid and ascorbic acid, and also good reproducibility was observed for seven electrodes. Moreover, the dopamine sensor exhibited a fast response time of less than 10 s. The wide range and acceptable sensitivity of the presented dopamine sensor provide the possible application in analysing the dopamine from the real samples.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.