Abstract-A Polymer gel mimicked human soft tissue was being fabricated using a monomer named 2-Hydroxyl-Ethyl-Acrylate (HEA) with the present of gelatin. The readymade gel which is the concentration for HEA fixed at 5% was then undergoes an ultrasonic evaluation to test for the propagation of sound speed through it. Sonic Waves Analyzer is absolutely the most accurate technique to determine the aims (changes of speed as function of polymer structure /stiffness over time). The fixed frequency of transducers involved is at 500 kHz by using the seismic reflection concept. In the observation of relationship between the ultrasound propagation speeds as the day increased, the propagation speed still varies between 1390 to 1500 m/s which is still in the range of speed of sound for human tissue.Index Terms-Tissue mimicking, ultrasound phantom, abdominal ultrasound, ultrasound propagation speed
Body sizes of patients undergoing x-ray examination vary in body mass index (BMI) and waist circumference (WC). This study aimed to evaluate the relationship between BMI and WC on the image quality of abdominal computed radiography (CR). Anteroposterior supine abdomen projection was conducted on 69 patients from Hospital Raja Perempuan Bainun, Ipoh using a Siemens Multixtop general x-ray unit, and the images were processed with CR Carestream Direct view Max. Samples were categorised into normal BMI (n = 23), overweight (n = 23) and obese (n = 23). Image quality was measured quantitatively in signal-to-noise ratio (SNR) and qualitatively by visual grading analysis (VGA) based on the Commission of the European Communities (CEC) image criteria. Data were analysed by analysis of variance (ANOVA) and Pearson's correlation for comparison and determining the relationship among BMI, WC and image quality. Results showed a significant difference (p < 0.01) in image quality of
Dual-energy CT allows the determination of tissue composition based on the different atomic numbers and attenuation profiles of the constituents. The aims of this study is to assess the feasibility of dual-energy CT at Imaging Unit, Advanced Medical, and Dental Institute, USM, to quantify different materials, permitting imaging assessment of elemental deficiencies, metabolic imbalances, and any abnormal tissue in clinical practice. The study was conducted at the Imaging Unit, Advanced Medical and Dental Institute, Universiti Sains Malaysia, Pulau Pinang, Malaysia. The study was performed using a new fabricated abdominal phantom for spectral CT imaging that scanned on the single-source, fast switching dual-energy CT scanner (Somatom Definition; Siemens AG, Wittelsbacherplatz Muenchen, Germany) system in dual-energy mode at tube voltages of 80 kVp for low energy and 140 kVp for high energy using abdominal protocol. The phantom was scanned at 4.0 mm slice thickness and pitch value 1.2 using CAREDose 4D (automated tube current modulation). Four tubes filled with calcium chloride, ferric nitrate, water, and sunflower oil that represents bone, blood, soft tissue, and fat respectively were analyzed in an abdominal phantom. Image post-processing was analyzed. All the tissue-mimicking materials, calcium chloride, ferric nitrate, water, and oil can be differentiated clearly in an unenhanced image scan. By applying the two different energy levels, all these materials can be accurately differentiated from one another based on their differential absorption levels of the x-ray energy. The material separation in the dual-energy CT technique is based on the attenuation interaction in the irradiated materials by applying varies x-ray beam at low and high energy. Furthermore, in clinical practice, a radiation source is usually composed of individual photons with a wide range of energies, and each photon energy is attenuated differently by the types of tissues in the human body. Material separation can be accurately quantified with a dual-energy CT system available at Universiti Sains Malaysia. Thus, the dual-energy CT capable of tissue characterization.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.