Clarity ultrasound (US) is an image-guided radiotherapy system used for tracking intrafraction prostate displacements in real time. The objectives of this study are to evaluate intrafraction prostate displacements and derive planning target volume (PTV) margins for prostate radiotherapy at our institution. The ultrasound (US) data of nine prostate cancer patients referred for VMAT radiotherapy was retrieved. Prior to beam on, patient position was set up with the US probe positioned transperineally with the aid of reference images (fused US and computed tomography images). In each fraction, prostate displacements in three directions [superior/inferior (SI), left/right (LR) and anterior/posterior (AP)] were recorded. PTV margins were determined using Van Herk's formula. To assess the prostate displacement time trend, continuous displacement data were plotted in 30-second intervals for eight minutes. The intrafraction prostate monitoring found a population mean setup error (M p ) of 0.8, 0.1, -1.7 mm, a systematic error of (∑ p ) 0.7, 0.4, 0.9 mm and random error (σ p ) of 0.2, 0.1, 0.3 mm in SI, LR and AP directions, respectively. The PTV margin was found to be the largest in the AP direction at 2.5 mm compared with 1.9 mm and 1.1 mm for SI and LR directions, respectively. The PTV margin allowed for prostate radiotherapy at our institution was 2.5 mm in all directions. The prostate displacement time trend showed an increase in intrafraction displacements. Clarity is feasible for monitoring intrafraction displacement of the prostate and may facilitate PTV margin generation to account for such displacements during radiotherapy.
Clarity ultrasound (US) is an image-guided radiotherapy system used for tracking intrafraction prostate displacements in real time. The objectives of this study are to evaluate intrafraction prostate displacements and derive planning target volume (PTV) margins for prostate radiotherapy at our institution. The ultrasound (US) data of nine prostate cancer patients referred for VMAT radiotherapy was retrieved. Prior to beam on, patient position was set up with the US probe positioned transperineally with the aid of reference images (fused US and computed tomography images). In each fraction, prostate displacements in three directions [superior/inferior (SI), left/right (LR) and anterior/posterior (AP)] were recorded. PTV margins were determined using Van Herk’s formula. To assess the prostate displacement time trend, continuous displacement data were plotted in 30-second intervals for eight minutes. The intrafraction prostate monitoring found a population mean setup error (Mp) of 0.8, 0.1, -1.7 mm, a systematic error of (∑p) 0.7, 0.4, 0.9 mm and random error (σp) of 0.2, 0.1, 0.3 mm in SI, LR and AP directions, respectively. The PTV margin was found to be the largest in the AP direction at 2.5 mm compared with 1.9 mm and 1.1 mm for SI and LR directions, respectively. The PTV margin allowed for prostate radiotherapy at our institution was 2.5 mm in all directions. The prostate displacement time trend showed an increase in intrafraction displacements. Clarity is feasible for monitoring intrafraction displacement of the prostate and may facilitate PTV margin generation to account for such displacements during radiotherapy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.