This study is designed to evaluate the N-terminal pro-BNP (NTproBNP) levels in patients with mitral stenosis (MS) and its possible correlation with clinical and echocardiographic parameters of the disease. The study group consisted of 29 patients with isolated MS (patients with greater mild regurgitation were excluded) and 20 normal control subjects of similar age and gender distribution. Blood samples for NTproBNP were collected at the time of clinical and echocardiographic examination. NTproBNP levels were elevated in patients with MS compared to controls (325 +/- 249 pg/dL [19.9-890] versus 43 +/- 36 pg/dL [5.76-193.3], P < 0.001). Patients with atrial fibrillation had significantly higher NTproBNP levels compared to those with sinus rhythm (561 +/- 281 pg/dL versus 254 +/- 194 pg/dL, P = 0.044). MS patients with sinus rhythm also had higher NTproBNP levels compared to controls (254 +/- 194 pg/dL versus 43 +/- 36 pg/dL, P = 0.00011). NT pro BNP levels correlated to the LA (R = 0.73, P < 0.0001) and RV (R = 0.41, P = 0.042) diameters, mitral valve area (R =-0.45, P = 0.025), mean mitral gradient (R = 0.57, P = 0.003), peak PAP (R = 0.7, P = 0.03), and NYHA functional class (R = 0.61, P = 0.007). In conclusion, serum NTproBNP levels correlate well with echocardiographic findings and functional class in patients with MS and can be used as a marker of disease severity. Additionally, it may have a potential use as an additional noninvasive and relatively cheap method in monitoring disease progression especially in patients with poor echocardiographic windows.
Although several left ventricular assist devices (LVADs) have been used widely, remote monitoring of LVAD parameters has been available only recently. We present our remote monitoring experience with an axial-flow LVAD (HeartAssist-5, MicroMed Cardiovascular, Inc., Houston, TX, USA). Five consecutive patients who were implanted a HeartAssist-5 LVAD because of end-stage heart failure due to ischemic (n=4) or idiopathic (n=1) cardiomyopathy, and discharged from hospital between December 2011 and January 2013 were analyzed. The data (pump speed, pump flow, power consumption) obtained from clinical visits and remote monitoring were studied. During a median follow-up of 253 (range: 80-394) days, fine tuning of LVADs was performed at clinical visits. All patients are doing well and are in New York Heart Association Class-I/II. A total of 39 alarms were received from three patients. One patient was hospitalized for suspected thrombosis and was subjected to physical examinations as well as laboratory and echocardiographic evaluations; however, no evidence of thrombus washout or pump thrombus was found. The patient was treated conservatively. Remaining alarms were due to insufficient water intake and were resolved by increased water consumption at night and summer times, and fine tuning of pump speed. No alarms were received from the remaining two patients. We believe that remote monitoring is a useful technology for early detection and treatment of serious problems occurring out of hospital thereby improving patient care. Future developments may ease troubleshooting, provide more data from the patient and the pump, and eventually increase physician and patient satisfaction. Despite all potential clinical benefits, remote monitoring should be taken as a supplement to rather than a substitute for routine clinical visits for patient follow-up.
SUMMARYExisting data on the effect of retained pacemaker leads on right ventricular (RV) and tricuspid valve function is limited.Objective: In this echocardiographic study we investigated the long-term effect of retained ventricular leads on RV and tricuspid valve function in patients with permanent pacemakers.Forty patients, 18 with two (group I) and 22 with one (group II) ventricular lead were assessed echocardiographically at an average of 39 months after the second lead implantation in group I and 80 months after the lead implantation in group II.The sum of the lead body diameter in group I was significantly greater than the body diameter in group II (P < 0.000). There was no significant difference between the groups with respect to chamber diameters and ventricular or valvular functions. The distributions of the different tricuspid regurgitation (TR) grades were similar, with the majority of patients in both groups having mild TR.Retained second pacemaker leads do not have an additional negative effect on right ventricular and tricuspid valve function. (Jpn Heart J 2004; 45: 103-108) Key words: Permanent pacemaker, Tricuspid regurgitation, Echocardiography, Retained leads LEAD dysfunction is one of the major problems/complications of permanent pacemaker therapy. Dysfunction due to mechanical or infective problems or electrical failure leads to replacement. Although lead extraction is done effectively and safely using the new extraction devices in many centers, there still exists a serious complication risk if it is done by inexperienced operators.1,2) Some of the functionless leads can not be removed safely and are left in situ if an absolute indication for extraction does not exist. It has been shown that the retained functionless pacemaker leads in the cardiovascular system are well tolerated unless they are infected and carry a very low complication rate. 3,4) Other possible comFrom the
Although from a limited number of selected patients, these findings indicate that repeat PMC is a safe and effective method, with follow-up results similar to a first intervention and should be considered as the first therapeutic option in suitable patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.