Introduction Reliable serum creatinine measurements are of vital importance for the correct classification of chronic kidney disease and early identification of kidney injury. The National Kidney Disease Education Programme working group and other groups have defined clinically acceptable analytical limits for creatinine methods. The aim of this study was to re-evaluate the performance of routine creatinine methods in the light of these defined limits so as to assess their suitability for clinical practice. Method In collaboration with the Dutch External Quality Assurance scheme, six frozen commutable samples, with a creatinine concentration ranging from 80 to 239 μmol/L and traceable to isotope dilution mass spectrometry, were circulated to 91 laboratories in four European countries for creatinine measurement and estimated glomerular filtration rate calculation. Two out of the six samples were spiked with glucose to give high and low final concentrations of glucose. Results Results from 89 laboratories were analysed for bias, imprecision (%CV) for each creatinine assay and total error for estimated glomerular filtration rate. The participating laboratories used analytical instruments from four manufacturers; Abbott, Beckman, Roche and Siemens. All enzymatic methods in this study complied with the National Kidney Disease Education Programme working group recommended limits of bias of 5% above a creatinine concentration of 100 μmol/L. They also did not show any evidence of interference from glucose. In addition, they also showed compliance with the clinically recommended %CV of ≤4% across the analytical range. In contrast, the Jaffe methods showed variable performance with regard to the interference of glucose and unsatisfactory bias and precision. Conclusion Jaffe-based creatinine methods still exhibit considerable analytical variability in terms of bias, imprecision and lack of specificity, and this variability brings into question their clinical utility. We believe that clinical laboratories and manufacturers should work together to phase out the use of relatively non-specific Jaffe methods and replace them with more specific methods that are enzyme based.
SummaryA lean 15-year-old girl was diagnosed with type 1 diabetes based on symptomatic hyperglycaemia and positive anti-islet cell antibodies. Glycaemia was initially stabilised on twice-daily mixed insulin. After 11 months from the time of diagnosis, she complained of hyperglycaemia and ketosis alternating with hypoglycaemia. This progressively worsened until prolonged hospital admission was required for treatment of refractory hypoglycaemia. A high titre of anti-insulin antibodies was detected associated with a very low recovery of immunoreactive (free) insulin from plasma after precipitation with polyethylene glycol, suggesting the presence of insulin in bound complexes. Insulin autoimmune syndrome was diagnosed and metabolic fluctuations were initially managed supportively. However, due to poor glucose control, immunosuppressive therapy was initiated first with steroids and plasmapheresis and later with anti-CD20 antibody therapy (Rituximab). This treatment was associated with a gradual disappearance of anti-insulin antibodies and her underlying type 1 diabetes has subsequently been successfully managed with an insulin pump.Learning points Anti-insulin antibodies may result in low levels of free insulin.Polyclonal anti-insulin antibodies can interfere with the pharmacological action of administered insulin, resulting in hypoglycaemia and insulin resistance, due to varying affinities and capacities.In this patient, rituximab administration was associated with a gradual disappearance of anti-insulin antibodies.It is hypothesised that this patient had subcutaneous insulin resistance (SIR) caused by insulin capture at the tissue level, either by antibodies or by sequestration.A prolonged tissue resistance protocol may be more appropriate in patients with immune-mediated SIR syndrome.
The hook effect is a well-recognized problem that can occur in assays of most tumour markers, including alpha feto-protein (AFP). We present a case of hepatoblastoma in a baby. The diagnosis was delayed as a result of unrecognized 'hooking' of a very high AFP concentration in the automated immunoassay method used. The falsely low result obtained was considered normal for the patient's age and supported the diagnosis of benign haemangioendothelioma. Liaison between clinical and laboratory staff was critical in obtaining an accurate AFP result, proceeding to liver biopsy and establishing the definitive diagnosis of hepatoblastoma. While the reasons and solutions for hook effect have been well researched and published, we believe the presence of extremely high serum AFP concentration in some hepatoblastoma patients means that the hook effect remains a problem and can generate erroneously low AFP results despite assay reformulation by manufacturers. Therefore constant vigilance by laboratory staff is still needed.
Introduction Reference intervals are dependent on the reference population, the analytical methods and the way the data are handled statistically. Individual method-related differences have been studied but the comparative differences in reference intervals have not. Methods We studied a reference population of healthy adult subjects and measured free thyroxine and thyroid-stimulating hormone by the four most commonly used analytical platforms used in the UK. Subjects were excluded if they were > 65 years or had positive thyroid peroxidase antibodies. We also performed a systematic literature review of thyroid hormone reference interval studies in non-pregnant adults. Results In total, 303 subjects were recruited and 42 excluded. The central 95th centile values for thyroid-stimulating hormone (mIU/L) were Abbott Architect (0.51-3.67); Beckman Unicel DxI (0.57-3.60); Roche Cobas (0.60-4.31) and Siemens Advia Centaur XP (0.63-4.29). The 95th centile values for thyroxine (pmol/L) were Abbott Architect (10.6-15.5); Beckman Unicel DxI (7.9-13.0); Roche Cobas (12.5-19.6) and Siemens Advia Centaur XP (11.8-19.0). We identified 55 papers describing thyroid reference intervals in male and non-pregnant female adults. The values for upper and lower reference intervals by manufacturer varied but were not significantly different for thyroid-stimulating hormone but were for thyroxine. Discussion Our study demonstrates clearly that there are marked variations in the reference intervals for thyroid hormones between analytical platforms. There is an urgent need for standardization of thyroid hormone assays to permit transferability of results. Until then, guidelines will need to reflect this method-related difference.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.