A multi-machine database for the H-mode scrape-off layer power fall-off length, λq in JET, DIII-D, ASDEX Upgrade, C-Mod, NSTX and MAST has been assembled under the auspices of the International Tokamak Physics Activity. Regression inside the database finds that the most important scaling parameter is the poloidal magnetic field (or equivalently the plasma current), with λq decreasing linearly with increasing Bpol. For the conventional aspect ratio tokamaks, the regression finds , yielding λq,ITER ≅ 1 mm for the baseline inductive H-mode burning plasma scenario at Ip = 15 MA. The experimental divertor target heat flux profile data, from which λq is derived, also yield a divertor power spreading factor (S) which, together with λq, allows an integral power decay length on the target to be estimated. There are no differences in the λq scaling obtained from all-metal or carbon dominated machines and the inclusion of spherical tokamaks has no significant influence on the regression parameters. Comparison of the measured λq with the values expected from a recently published heuristic drift based model shows satisfactory agreement for all tokamaks.
On the basis of an analysis of the ITER L-mode energy confinement database, two new scaling expressions for tokamak L-mode energy confinement are proposed, namely a power law scaling and an offset-linear scaling. The analysis indicates that the present multiplicity of scaling expressions for the energy confinement time T E in tokamaks (Goldston, Kaye, Odajima-Shimomura, Rebut-Lallia, etc.) is due both to the lack of variation of a key parameter combination in the database, f s = 0.32 R a" 075 k 0 5 ~ A a O25 k 05 , and to variations in the dependence of r E on the physical parameters among the different tokamaks in the database. By combining multiples of f s and another factor, f q = 1.56 a 2 kB/RI p = q eng /3.2, which partially reflects the tokamak to tokamak variation of the dependence of T E on q and therefore implicitly the dependence of T E on I p and n,., the two proposed confinement scaling expressions can be transformed to forms very close to most of the common scaling expressions. To reduce the multiplicity of the scalings for energy confinement, the database must be improved by adding new data with significant variations in f s , and the physical reasons for the tokamak to tokamak variation of some of the dependences of the energy confinement time on tokamak parameters must be clarified.
The paper describes the content of an H-mode confinement database that has been assembled for the ITER project. Data were collected from six machines of different sizes and shapes: ASDEX, DIII-D, JET, JFT-2M, PBX-M and PDX. A detailed description of the criteria used in the selection of the data and the definition of each of the variables is given. The paper also presents an analysis of the conditions of the database, the scalings (power law and offset linear) of the data with both dimensional and dimensionless variables, and predictions of the expected confinement time for ITER.
Recent experiments at ASDEX Upgrade have achieved advanced scenarios with high β N (>3) and confinement enhancement over ITER98(y, 2) scaling, H H98y2 = 1.1-1.5, in steady state. These discharges have been obtained in a modified divertor configuration for ASDEX Upgrade, allowing operation at higher triangularity, and with a changed neutral beam injection (NBI) system, for a more tangential, off-axis beam deposition. The figure of merit, β N H ITER89-P , reaches up to 7.5 for several seconds in plasmas approaching stationary conditions. These advanced tokamak discharges have low magnetic shear in the centre, with q on-axis near 1, and edge safety factor, q 95 in the range 3.3-4.5. This q-profile is sustained by the bootstrap current, NBI-driven current and fishbone activity in the core. The off-axis heating leads to a strong peaking of the density profile and impurity accumulation in the core. This can be avoided by adding some central heating from ion cyclotron resonance heating or electron cyclotron resonance heating, since the temperature profiles are stiff in this advanced scenario (no internal transport barrier). Using a combination of NBI and gas fuelling line, average densities up to 80-90% of the Greenwald density are achieved, maintaining good confinement. The best integrated results in terms of confinement, stability and ability to operate at high density are obtained in highly shaped configurations, near double null, with δ = 0.43. At the highest densities, a strong reduction of the edge localized mode activity similar to type II activity is observed, providing a steady power load on the divertor, in the range of 6 MW m −2 , despite the high input power used (>10 MW).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.