The insertion of the Veress needle in the abdominal midline, at the umbilicus, poses serious risk to the life of patients. Therefore, further studies should be conducted to investigate alternative sites for Veress needle insertion.
Transitory, high intraperitoneal pressure (20 mmHg for 5 min) for insertion of the first trocar resulted in changes in HR, MAP, ETCO(2), and ITP that were within the normal range, and no adverse clinical effects were observed. Therefore, the use of transitory, high intraperitoneal pressure is recommended to prevent iatrogenic injury during blind insertion of the first trocar. Nevertheless, it is not clear that this method would be safe in patients with moderate to severe chronic obstructive pulmonary disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.