Treatment of rabbit corneas, with either WST11/NIR or WST-D/NIR, increases their biomechanical strength through a mechanism that does not involve singlet oxygen. The WST-D/NIR treatment showed less adverse effects, demonstrating a new potential for clinical use in keratoconus and corneal ectasia after refractive surgery.
The purpose of this study was to describe a novel device that may serve as an alternative to Descemet membrane endothelial keratoplasty (DMEK) for the treatment of chronic corneal edema. Methods:The EndoArt (EyeYon Medical, Israel) is a flexible, 50mm thin artificial endothelial layer that matches the cornea's posterior curvature and functions as a fluid barrier at the posterior stroma, replacing the diseased endothelium. Similar to a DMEK approach, it is implanted into the anterior chamber, carefully positioned on the posterior stroma, and secured using an air-gas mixture. Two patients with chronic corneal edema resulting from endothelial decompensation underwent implantation of the new artificial lamella. Results:In patient 1, the central corneal thickness (CCT) decreased from 730 mm preoperatively to 593 mm at 1 day postoperatively. In patient 2, the CCT decreased from 761 mm preoperatively to 487 mm at 1 day postoperatively. Both patients reported high satisfaction and an overall brighter visual quality. Although dislocation of the lamella occurred in both cases, the CCT was promptly restored after a repositioning procedure and remained stable at the 17-month followup (CCT of 526 and 457 mm for patients 1 and 2, respectively). In contrast to DMEK donor tissue, the artificial lamella is sufficiently robust to allow easy intraocular manipulation without the risk of damaging the implant. It is easily removable and does not require any immunosuppressive treatment because of its nonbiological nature.Conclusions: Implantation of the EndoArt led to rapid corneal deturgescence and CCT restoration, presenting a possible option for patients with chronic corneal edema.
Introduction. To compare the safety and efficacy of the Therapeutic Hyper-CL™ lens versus a standard bandage contact lens (PureVision B&L) for chronic corneal edema. Methods. Prospective, multicenter, randomized, crossover study. Chronic corneal edema patients were randomized to one of two arms. The first arm was fitted with the Therapeutic Hyper-CL™ lens while the second arm was fitted with a standard soft bandage contact lens. Both arms were treated with 5% sodium chloride 6 times a day. After a 7-day treatment period, there was a 7-day washout period, after which the arms were crossed over. Patients were evaluated at days 0 (baseline), 7 (following first treatment allocation), 14 (following washout), and 21 (following second treatment allocation). The primary outcomes were 3 lines of BCVA (best corrected visual acuity) improvement. Results. In total, 49 patients were enrolled. There was significantly greater BCVA improvement rate >3 lines (30.4% versus 17.4%, P=0.04) in the Therapeutic Hyper-CL™ lens group. The mean change in BCVA lines was significantly greater for the Therapeutic Hyper-CL™ lens (3.4 ± 6.7 versus 0.9 ± 2.3, P=0.02). Conclusions. The Therapeutic Hyper-CL™ lens was associated with a higher chance for significant visual acuity improvement when compared to a standard bandage contact lens combined with 5% sodium chloride. This trial is registered with NCT02660151.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.