Background:The current outbreak of SARS-CoV-2 has spread to almost every country with more than three million confirmed cases and over two hundred thousand deaths as of April 28, 2020. Rapid first-line testing protocols are needed for outbreak control and surveillance. Methods: We used computational and manual design to generate a suitable set of RT-RPA primer and exo-IQ probe sequences targeting the SARS-CoV-2 N gene. RT-RPA sensitivity was determined by amplification of in vitro transcribed RNA standards. Assay selectivity was demonstrated by means of a selectivity panel of 32 nucleic acid samples derived from common respiratory viruses. To validate the assay against full-length SARS-CoV-2 RNA, total viral RNA derived from cell culture supernatant and 19 nasopharyngeal swab samples (8 positive and 11 negative for SARS-CoV-2) were screened. All results were compared to established RT-qPCR assays. Results: The 95 % detection probability of the RT-RPA assay was determined to be 7.74 (95% CI: 2.87 -27.39) RNA copies per reaction. The assay showed no crossreactivity to any other screened coronaviruses as well as respiratory viruses of clinical significance. The developed RT-RPA assay produced 100% diagnostic sensitivity and specificity when compared to RT-qPCR (n=20). Conclusions: With a run time of 15 to 20 minutes and first results being available in under 7 minutes for high RNA concentrations, the reported assay constitutes one of the fastest nucleic acid based detection methods for SARS-CoV-2 to date and may provide a simple to use alternative to RT-qPCR for first-line screening at the point of need. Downloaded from https://academic.oup.com/clinchem/advance-article-abstract/doi/10.1093/clinchem/hvaa116/5834714 by guest on 09 June 2020
In March 2020, the SARS-CoV-2 virus outbreak was declared as a world pandemic by the World Health Organization (WHO). The only measures for controlling the outbreak are testing and isolation of infected cases. Molecular real-time polymerase chain reaction (PCR) assays are very sensitive but require highly equipped laboratories and well-trained personnel. In this study, a rapid point-of-need detection method was developed to detect the RNA-dependent RNA polymerase (RdRP), envelope protein (E), and nucleocapsid protein (N) genes of SARS-CoV-2 based on the reverse transcription recombinase polymerase amplification (RT-RPA) assay. RdRP, E, and N RT-RPA assays required approximately 15 min to amplify 2, 15, and 15 RNA molecules of molecular standard/reaction, respectively. RdRP and E RT-RPA assays detected SARS-CoV-1 and 2 genomic RNA, whereas the N RT-RPA assay identified only SARS-CoV-2 RNA. All established assays did not cross-react with nucleic acids of other respiratory pathogens. The RT-RPA assay’s clinical sensitivity and specificity in comparison to real-time RT-PCR (n = 36) were 94 and 100% for RdRP; 65 and 77% for E; and 83 and 94% for the N RT-RPA assay. The assays were deployed to the field, where the RdRP RT-RPA assays confirmed to produce the most accurate results in three different laboratories in Africa (n = 89). The RPA assays were run in a mobile suitcase laboratory to facilitate the deployment at point of need. The assays can contribute to speed up the control measures as well as assist in the detection of COVID-19 cases in low-resource settings.
PCR inhibitors in clinical specimens negatively affect the sensitivity of diagnostic PCR and RT-PCR or may even cause false-negative results. To overcome PCR inhibition, increase the sensitivity of the assays and simplify the detection protocols, simple methods based on quantitative nested real-time PCR and RT-PCR were developed to detect exogenous DNA and RNA directly from large volumes of whole human blood (WHB). Thermus thermophilus (Tth) polymerase is resistant to several common PCR inhibitors and exhibits reverse transcriptase activity in the presence of manganese ions. In combination with optimized concentrations of magnesium ions and manganese ions, Tth polymerase enabled efficient detection of DNA and RNA from large volumes of WHB treated with various anticoagulants. The applicability of these methods was further demonstrated by examining WHB specimens collected from different healthy individuals and those stored under a variety of conditions. The detection limit of these methods was determined by detecting exogenous DNA, RNA, and bacteria spiked in WHB. To the best of our knowledge, direct RNA detection from large volumes of WHB has not been reported. The results of the developed methods can be obtained within 4 hours, making them possible for rapid and accurate detection of disease-causing agents from WHB.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.