The purpose of this research was to investigate how different pipe, gutter, and storage tank materials, time of contact, and pH affect water quality. The tests were conducted using a series of controlled laboratory experiments for a period of three months by immersing sections of the test materials in large quantities of pH buffer solutions made using locally collected roof runoff and storm drain inlet water. The tests were conducted at pH 5 and pH 8. Water samples were periodically collected and then analyzed for a broad range of metallic and nutrient constituents and toxicity utilizing Microtox procedure. Copper release from copper gutters increased with decreased pH. The highest concentrations of zinc were observed from galvanized materials. Decreasing the pH increased zinc concentration from galvanized steel materials during the first 27 hours of exposure. Galvanized steel materials were the only source of lead concentrations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.