Abstract. Method of virtual prototyping with the following mathematical modeling was used to simulate the heat-mass exchange and combustion during the operation of high-temperature gas infrared radiators, and to find optimal technical solutions for its design. The most authoritative and approved software product Ansys Multiphysics was used. The results of the mathematical modeling of heat and mass transfer in a turbulent reaction medium with combustion reproduce the experimental data produced by a measurement in real operating conditions of the gas-fired infrared heat emitter. The temperature distribution along the height of the ceramic nozzle was established. Obtained results enable estimation of the ignition and combustion zones.
The paper presents the results of the simulation of convectional heat transfer in buildings with radiant gas heating. The study is provided by numerical researches based on existing buildings and numerical studies with the use of modern software ANSYS Multiphysics Fluent, Autodesk Inventor. The data reliability is ensured by the use of fundamental laws in regards to numerical researches and approved mathematic models application; certificated measuring equipment; licensed software products; matching of numerical and experimental researches; matching of the simulation with other works. The simulation of luminous infrared gas emitters of all thermal powers (5, 10, 15, 20, 30, 40 kW) in pre-wall and central placements at heights of 4, 5, 6, 7, 8, 9, 10 m was conducted. Gas-fired infrared heat emitters with heat output of 5, 10, 15, 20, 30, 40 kW were studied. Obtained function of IR-heated zone diameter is close to logarithmic function of thermal output. Effective emitter placement heights and least horizontal pitch for the given room volume were determined.
The purpose of this work is to analyze the efficiency of the technical solution that is based on thermal insulation of the infrared radiant burner outer surface and to identify of the characteristics of combustion and heat and mass exchange processes. Calculation of the heat balance is performed for thermal capacities of 5, 10, 15, 20, 30, 40 kW and proceeding from the main goal that was to generate directed local heating of workplaces and production areas. We used Ansys Multiphysics software and Fluent CFD solver to implement finite element analysis. Calculation of the thermal insulation layer thickness for a given external surface temperature was additionally performed. The technical solutions offered provides an optimal thermal regime in the whole building and enable us to increase the efficiency of the high temperature infrared radiant emitter to 2-17% and a consequence of the system as a whole.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.